Operations Manual SC-610
Page 25
Harmonic Drive AG
900105
11/2005
Control Input Wiring:
4.2.2 Control Outputs
The control outputs must be supplied with an external voltage. The wiring of the control outputs is optional
and not necessary for proper drive operation.
Control Output Function:
Signal name
Connector
Switch Position / Function
Pin
active / closed
not active / open
FAULT+
FAULT -
X3.4
X3.5
Controller happy - no fault
Controller not happy - drive
fault
DOUT 0
X3.18
Digital output 0 = logical 1
Digital output 0 = logical 0
DOUT 1
X3.19
Digital output 1 = logical 1
Digital output 1 = logical 0
DOUT 2,
DrOK
X3.20
Digital output 2 = active - no
fault
Digital output 2 not active =
drive fault
More about control outputs:
"FAULT":
This output is a relay contact and consists of two connector pins. It indicates the general
drive status.
The FAULT relay contact is not suitable for switching inductive
loads (relays). Inductive loads can cause some nuisance drive
faults.
"DrOK":
This output has the same functionality than the fault relay output. The output (+24V) is
activated in case the drive is ready for work.
"DOUT x":
These outputs can be used together with the drive internal PLC program. There are 2 digital
outputs available.
Содержание SC-610 Series
Страница 1: ...Operations Manual AC Servo Controller SC 610 No 900105 11 2005 24 11 2005 FA...
Страница 3: ......
Страница 52: ...Operations Manual SC 610 Page A1 Harmonic Drive AG 900105 11 2005 APPENDIX...
Страница 64: ...Operations Manual SC 610 Page A13 Harmonic Drive AG 900105 11 2005 APPENDIX G...
Страница 65: ...Page A14 Operations Manual SC 610 Harmonic Drive AG 900105 11 2005 APPENDIX H...
Страница 66: ...Operations Manual SC 610 Page A15 Harmonic Drive AG 900105 11 2005 APPENDIX I...
Страница 67: ...Page A16 Operations Manual SC 610 Harmonic Drive AG 900105 11 2005 APPENDIX J...
Страница 68: ...Operations Manual SC 610 Page A17 Harmonic Drive AG 900105 11 2005 APPENDIX K...
Страница 69: ......