Page 24
Operations Manual SC-610
Harmonic Drive AG
900105
11/2005
Preset timing diagram:
Time
Trigger Pulse
(at least 2ms)
Profiler
Latency
DIN0 ..
DIN3
Trigger
Input
Profiler
Re-trigger Time (2ms minimum)
Setup inputs
Time
Time
Functional example of control inputs:
The wiring of the control inputs is also shown in chapter 4.3 .
The picture on the right hand side shows the function
and the two wiring principles of the control inputs:
The two wiring versions are:
1)
Switching to the external control input power sup-
ply. The switch will be linked between the control
input (X3.x) and the external power supply (Vext).
The ground return (GNDext) is permanently wired
with CREF (X3.7).
2)
Switch to the ground return of the external power
supply. The switch will be linked between the con-
trol input and the external ground return (GNDext).
The external power supply (Vext) is permanently
wired with CREF (X3.7).
Voltage range of Vext : +12 ... 29VDC
X3.x: "x" for connector pin,
e.g. x=9
→
X3.9 = Enable-Input
V
ext
GND
V
GND
Drive
Drive
X3.7
X3.7
X3.x
X3.x
SWITCH TO
V
ext
ext
GND
ext
ext
ext
The control inputs only operate, if they are supplied with an
external voltage.
Содержание SC-610 Series
Страница 1: ...Operations Manual AC Servo Controller SC 610 No 900105 11 2005 24 11 2005 FA...
Страница 3: ......
Страница 52: ...Operations Manual SC 610 Page A1 Harmonic Drive AG 900105 11 2005 APPENDIX...
Страница 64: ...Operations Manual SC 610 Page A13 Harmonic Drive AG 900105 11 2005 APPENDIX G...
Страница 65: ...Page A14 Operations Manual SC 610 Harmonic Drive AG 900105 11 2005 APPENDIX H...
Страница 66: ...Operations Manual SC 610 Page A15 Harmonic Drive AG 900105 11 2005 APPENDIX I...
Страница 67: ...Page A16 Operations Manual SC 610 Harmonic Drive AG 900105 11 2005 APPENDIX J...
Страница 68: ...Operations Manual SC 610 Page A17 Harmonic Drive AG 900105 11 2005 APPENDIX K...
Страница 69: ......