background image

Harmonic Drive AG

CPU-H/ CPU-S Units

Tabelle/

Table 2

6

6..3

3

O

Ou

uttp

pu

utt  b

beea

arriin

ng

g  

The output bearing is delivered with lifetime lubrica-

tion. Re-lubrication is not necessary.

7

7

D

Diissp

po

ossa

all/

/  H

Heea

alltth

h  P

Prro

otteeccttiio

on

n

This Harmonic Drive product includes lubricati-

on for the gear component set and output bea-

ring. It is therefore necessary to dispose of the pro-

duct correctly according to national and local direc-

tives.

As lubricants (grease and oil) are hazardous substances,
they have to be handled according to the valid health
protection directives. If necessary, we can provide our
current safety data sheet.

6

6..3

3

A

Ab

bttrriie

eb

bsslla

ag

ge

err

Das Abtriebslager ist lebensdauerge-
schmiert. Nachschmieren ist nicht erfor-
derlich.

7

7

E

En

nttsso

orrg

gu

un

ng

g/

/   G

Ge

essu

un

nd

dh

he

eiittss--

sscch

hu

uttzz

Dieses Harmonic Drive Produkt bein-
haltet Schmierstoffe für den Getriebe-
einbausatz und das Abtriebslager. Auf
fachgerechte Entsorgung entsprechend
der nationalen und örtlichen Vorschriften muss
daher geachtet werden.

Da Schmierstoffe (Fette und Öle) Gefahrstoffe sind,
und entsprechend den gültigen Gesundheitsschutz-
vorschriften behandelt werden sollten, empfehlen
wir bei Bedarf das gültige Sicherheitsdatenblatt bei
uns anzufordern.

Hersteller

Manufacturer

Aral

BP

DEA

Esso

(Exxon)

Klüber

Mobil

Optimol

Shell

Texaco

Bezeichnung

Designation

Degol

BG 68

Energo

IGR-XP68

Falcon

CLP 68

Spartan

EP68

GEM
1-68

Mobil

Gear 626

Optigear

BM 68

Omala

Oil 68

Meropa

68

Freigegebene Schmieröle/

Permitted oil lubricants

6

6..2

2

G

Ge

ettrriie

eb

be

e  m

miitt  Ö

Öllsscch

hm

miie

erru

un

ng

g

Der erste Ölwechsel sollte nach etwa 100
Betriebsstunden durchgeführt werden. Anschließen-
de Wechselintervalle hängen von der Belastung ab, soll-
ten jedoch in einem Zeitraum von etwa 1000 Betriebs-
stunden durchgeführt werden. 

Zum Ölwechsel muss das alte Öl vollständig abgelassen
werden und neues Öl eingefüllt werden. Weitere
Informationen hierzu finden Sie im Kapitel 3.2.
Mögliche Schmieröle sind in Tabelle 2 angegeben. Die
Mischung von Schmiermitteln mit unterschiedlicher
Spezifikation ist grundsätzlich zu vermeiden. 

6

6..2

2

O

Oiill  llu

ub

brriicca

attiio

on

n  

The first oil change is necessary after 100 hours of
operation. Subsequent oil change intervals depend on
the operating conditions, but should take place at
intervals of approximately 1000 running hours. 

To change the oil, the used oil must be drained com-
pletely and fresh oil must be filled in. Further infor-
mation regarding oil lubrication can be found in
chapter 3.2 and permitted oil types are given in Table
2. The mixture of lubricants of different specifications
should generally be avoided.  

900140

11/2005

11

Содержание Precision CPU-H Series

Страница 1: ...900140 11 2005 Harmonic Drive AG Montage und Wartungsanleitung Assembly and Service Manual Units Baureihe CPU H CPU S CPU H CPU S Series Units Pr zision Precision...

Страница 2: ...E En nt ts so or rg gu un ng g G Ge es su un nd dh he ei it ts ss sc ch hu ut tz z 1 11 1 8 8 H Ha af ft tu un ng gs sa au us ss sc ch hl lu us ss s 1 12 2 1 1 S Se ec ct ti io on na al l D Dr ra aw w...

Страница 3: ...Sc ch hn ni it tt tz ze ei ic ch hn nu un ng g Abb 1 zeigt die Standard CPU H und CPU S Unit jeweils im Halbschnitt 1 1 S Se ec ct ti io on na al l D Dr ra aw wi in ng g Fig 1 shows the standard CPU...

Страница 4: ...l durch zuf hren Das Getriebe darf nur zur bestimmungsgem en Verwendung als Getriebe eingesetzt werden Aus sicherheitstechnischen und thermischen Gr nden ist der Betrieb nur bei vollst ndiger Verschra...

Страница 5: ...er die Radialwellendichtungen zus tzlich vorspannt In diesem Fall kann der Wirkungsgrad der Unit geringer als der gem Katalog berechnete Wirkungsgrad sein 2 2 4 4 W Wa ar rr ra an nt ty y Liabilities...

Страница 6: ...at the running surface of the out put shaft seal is prevented The material of all oil seals is FPM Viton The output bearing oil seal is provided with an additional protective lip shape AS At the inpu...

Страница 7: ...indicated on the custo mer drawing High performance 4BNo 2 grease with improved characteristics is also available for these products 3 3 2 2 G Ge ea ar rs s w wi it th h o oi il l l lu ub br ri ic ca...

Страница 8: ...chten Sie bitte die Angaben in Kapitel 3 Valid for CPU H series 4 4 2 2 A Au ux xi il li ia ar ry y m ma at te er ri ia al ls s f fo or r a as ss se em mb bl ly y For the assembly we recommend the app...

Страница 9: ...zeigt dass sich die Fettwechsel intervalle beim Einsatz des Fettes 4B No 2 im Vergleich zu den Fett Typen SK 1A bzw SK 2 ca um den Faktor 6 verl ngern 6 6 M Ma ai in nt te en na an nc ce e a an nd d L...

Страница 10: ...tions until grease change at rated torque Fig 3 Tr Rated torque cf catalogue Tav Average torque based on current load data This means that for 4B No 2 grease and a temperatu re of 50 C a grease change...

Страница 11: ...ige Sicherheitsdatenblatt bei uns anzufordern Hersteller Manufacturer Aral BP DEA Esso Exxon Kl ber Mobil Optimol Shell Texaco Bezeichnung Designation Degol BG 68 Energo IGR XP68 Falcon CLP 68 Spartan...

Страница 12: ...nachfolgen den Auflagen enthalten F r Verbesserungsvorschl ge sind wir dankbar 8 8 D Di is sc cl la ai im me er r o of f L Li ia ab bi il li it ty y Every effort is made to provide accurate and comple...

Отзывы: