background image

Harman®  •  PF-120 Installation Manual_R1  •  2014 -___  •  03/14

15

3-90-08121i

G. Fire Safety

To provide reasonable fire safety, the following should be 

given serious consideration:
•  Install at least one smoke detector on each floor of your 

home.

•  Locate smoke detector away from the heating appliance 

and close to the sleeping areas. 

•  Follow the smoke detector manufacturer’s placement and 

installation instructions and maintain regularly. 

•  Conveniently locate a Class A fire extinguisher to contend 

with small fires.

•  In the event of a hopper fire:

•  Evacuate the house immediately.
•  Notify fire department.

•  Installation and use of any damaged appliance. 
•  Modification of the appliance.
•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation  and/or  use  of  any  component  part  not 

approved by Hearth & Home Technologies.

•  Operating  appliance  without  fully  assembling  all 

components.

•  Do NOT Overfire.

Or any such action that may cause a fire hazard.

Fire Risk:

Hearth  &  Home Technologies  disclaims 

any responsibility for, and the warranty will 

be voided by, the following actions: 

Inspect  appliance  and  components  for 

damage.  Damaged  parts  may  impair  safe 

operation.
•  Do NOT install damaged components.
•  Do NOT install incomplete components.
•  Do NOT install substitute components.
Report damaged parts to dealer.

WARNING

!

WARNING

!

DO NOT RELOCATE OR BYPASS ANY OF THE 

SAFETY CONTROLS IN THE ORIGINAL FURNACE 

INSTALLATION.

WARNING

!

Vent Configurations:

To  reduce  probability  of  reverse  drafting  during  shut-

down  conditions,  Hearth  &  Home  Technologies  strongly 

recommends:

•  Installing the pellet vent with a minimum vertical run of 

five feet, preferably terminating above the roof line.

•  Installing the outside air intake at least four feet below the 

vent termination.

To prevent soot damage to exterior walls of the building and 

to prevent re-entry of soot or ash into the building:

•  Maintain specified clearances to windows, doors, and air 

inlets.

•  Vents should not be placed below ventilated soffits. Run 

the vent above the roof.

•  Avoid venting into alcove locations.
•  Vents should not terminate under overhangs, decks or 

onto covered porches.

•  Maintain  minimum  clearance  of  12  inches  from  the 

vent termination to the exterior wall. If you see deposits 

developing  on  the  wall,  you  may  need  to  extend  this 

distance to accommodate your installation conditions.

Hearth & Home Technologies assumes no responsibility 

for, nor does the warranty extend to, smoke damage 

caused by reverse drafting of pellet appliances under 

shut-down or power failure conditions.

Содержание PF-120

Страница 1: ...allation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirements in y...

Страница 2: ...s Specifications 4 C Electrical Rating 4 D Mobile Home Approvals 4 E BTU Efficiency Specifications 4 2 Getting Started A Tools and Supplies Needed 5 B Inspect Appliance and Components 5 3 Clearances A...

Страница 3: ..._________ Electrical Section 1 Pg 4 120VAC unswitched power provided to the appliance ________________________________ Finishing Sections 3 4 Pg 8 14 Combustible materials not installed in non combust...

Страница 4: ...to the frame of the mobile home and use only listed pellet vent Class PL connector pipe A Harman Outside Air Kit must be installed in a mobile home installation MODEL Pellet Furnace PF 120 LABORATORY...

Страница 5: ...g the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT install damaged incomplete or substitute components Keep appl...

Страница 6: ...iagram Dimensions are actual appliance dimensions Use for reference only 14 18 25 966 62 474 15 883 9 743 37 961 18 11 00 65 525 20 065 25 254 16 802 3 215 44 478 WITHOUT BLOWER BOX INSTALLED 27 238 2...

Страница 7: ...sh pan door The 18 clearance from the hopper end is a manufacturer s recommendation for adding pellets and or servicing the feeder mechanism The minimum clearance to the top of the plenum is 4 Fig 3 3...

Страница 8: ...The United States J Floor Protection Requirements US Sides 8 K Front 18 C Floor Protection The shaded area indicates the required floor protection area The furnace requires 48 x 52 of floor protectio...

Страница 9: ...onfiguration Graph under Section B Locating Your Appliance Chimney Each Vertical 90 or T subtract 2 5 feet Each Vertical 45 subtract 1 5 feet Each Horizontal 90 or T subtract 5 0 feet Each Horizontal...

Страница 10: ...intain specified clearances to windows doors and air inlets including air conditioners Vents should not be placed below ventilated soffits Avoid venting into alcove locations Vents should not terminat...

Страница 11: ...fsets Consider the appliance location relative to floor and ceiling and attic joists DO NOT CONNECT THIS UNIT TOACHIMNEY FLUE SERVICING ANOTHER APPLIANCE May allow flue gases to enter the house CAUTIO...

Страница 12: ...regulator assembly when measured from the horizontal center line of the regulator I The clearance to service regulator vent outlet must be a minimum of 6 feet J The clearance to a non mechanical air s...

Страница 13: ...ombine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When...

Страница 14: ...nd chimney To measure the draft or negative pressure on your appliance use a magnahelic or a digital pressure gauge capable of reading 0 1 inches of water column W C The appliance should be running on...

Страница 15: ...NOT install damaged components Do NOT install incomplete components Do NOT install substitute components Report damaged parts to dealer WARNING WARNING Do not relocate or bypass any of the safety cont...

Страница 16: ...y the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume some air needed for the stove especially during a power failure It may be neces...

Страница 17: ...is access to the combustion blower and flue area 1 Place the bottom on the floor The edge closest to the knockouts will be the edge towards the furnace See Figure 5 1 2 Place the desired vertical pan...

Страница 18: ...bottom middle hole under the filter opening NOTE Do not put any screws into any of the top holes at this time Filter Frame Panel Filter opening must be up 4 Place the remaining panel in this case the...

Страница 19: ...sure that the setscrew on the flex connector is not pointing toward the furnace end of the box when the locknut is fully tightened The filter box is now ready to install onto the furnace Note The blo...

Страница 20: ...Y DUCT WORK OR IN FREE AIR WILL CAUSE MOTOR OVERLOAD AND PREMATURE FAILURE 3 Mount the filter box on the furnace with 6 10 x 3 4 Tek screws 3 on each side Figure 5 10 Visually locate these holes so yo...

Страница 21: ...Orange Blue White Orange White Blue This section is not used on this unit CAUTION With this small gauge of wire care must be taken not to over tighten the terminal screws thus breaking the wire There...

Страница 22: ...dampers 2 should be installed in the ductwork 1 in the warm air supply duct for the existing furnace and 1 in the warm air supply duct of the pellet furnace after or downstream of the high limit fan c...

Страница 23: ...ct system can be installed to fit the customers needs Velocity 500fpm 700fpm 900fpm Static In W C 3 Minimum to 6 Maximum 1638 cfm 470 in 360 in 290 in These duct sizes are only recommendations The Ret...

Страница 24: ...blower size is 75 to 1 CFM for each square foot of conditioned space standard 8 ceiling height This furnace can be fitted with an air conditioning coil mounted in the supply air plenum HHT is not resp...

Страница 25: ...t the WHITE and SKY BLUE wires to the LIMIT switch It doesn t matter which wire is on which screw Figure 5 17 8 Make sure that all of the wires are out of the way when closing the cover Excess twistin...

Страница 26: ...ply 120 VAC 60Hz power stable enough to operate the control board properly Control board damage could occur Checking Recording the Low Draft After the venting is completed the firebox low draft will n...

Страница 27: ...shall comply with CSA B139 The installation of a gas furnace shall comply with the applicable requirements of CSA B365 and if changes are made to the installation of the gas furnace including clearanc...

Страница 28: ...WHITE GREEN N L BROWN DRK BLUE VIOLET BROWN BLACK RED BROWN G R E E N WHITE WHITE GREEN WHITE BROWN SKY BLUE WHITE RED BROWN WHITE BLACK SKY BLUE YELLOW HIGH VOLTAGE YELLOW VIOLET SKY BLUE WHITE 3 8...

Страница 29: ...Harman PF 120 Installation Manual_R1 2014 ___ 03 14 29 3 90 08121i...

Страница 30: ...n U S A Copyright 2012 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstove com Please contact your Harman dealer with any questions or concerns For...

Отзывы: