G. Fire Safety
To provide reasonable fire safety, the following should be
given serious consideration:
• Install at least one smoke detector on each floor of your
home.
• Locate smoke detector away from the heating appliance
and close to the sleeping areas.
• Follow the smoke detector manufacturer’s placement and
installation instructions and maintain regularly.
• Conveniently locate a Class A fire extinguisher to contend
with small fires.
• In the event of a hopper fire:
• Evacuate the house immediately.
• Notify fire department.
• Installation and use of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Do NOT Overfire.
Or any such action that may cause a fire hazard.
Fire Risk:
Hearth & Home Technologies disclaims
any responsibility for, and the warranty will
be voided by, the following actions:
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
WARNING
!
WARNING
!
DO NOT RELOCATE OR BYPASS ANY OF THE
SAFETY CONTROLS IN THE ORIGINAL FURNACE
INSTALLATION.
WARNING
!
Vent Configurations:
To reduce probability of reverse drafting during shut-
down conditions, Hearth & Home Technologies strongly
recommends:
• Installing the pellet vent with a minimum vertical run of
five feet, preferably terminating above the roof line.
• Installing the outside air intake at least four feet below the
vent termination.
To prevent soot damage to exterior walls of the building and
to prevent re-entry of soot or ash into the building:
• Maintain specified clearances to windows, doors, and air
inlets.
• Vents should not be placed below ventilated soffits. Run
the vent above the roof.
• Avoid venting into alcove locations.
• Vents should not terminate under overhangs, decks or
onto covered porches.
• Maintain minimum clearance of 12 inches from the
vent termination to the exterior wall. If you see deposits
developing on the wall, you may need to extend this
distance to accommodate your installation conditions.
Hearth & Home Technologies assumes no responsibility
for, nor does the warranty extend to, smoke damage
caused by reverse drafting of pellet appliances under
shut-down or power failure conditions.