6
Martin
®
ELP PAR User Guide
Before using the fixture, check that all power distribution
equipment and cables are in perfect condition and rated for
the current requirements of all connected devices.
Use only Neutrik PowerCON TRUE1 TOP cable connectors to
connect to the fixture’s power sockets.
Do not connect devices to power in a chain that will exceed
the electrical ratings of any cable or connector used in the
chain.
To connect fixtures to mains power in a chain, you must first
obtain 12 AWG or 2.5 mm
2
power input and throughput cables
that are 16 A rated and temperature-rated to suit the
application. In the USA and Canada the cables must be UL-
listed, type SJT or equivalent. In the EU the cables must be
type H05VV-F or equivalent. Suitable cables with Neutrik
PowerCON TRUE1 TOP connectors are available from Martin
(see
on page 46). If you use these cables, you
can connect fixtures to power in a linked chain, POWER OUT
throughput socket to POWER IN input socket, but do not link
more than:
•
four (4) ELP PAR fixtures in total at 100-120 V, or
•
seven (7) ELP PAR fixtures in total at 200-240 V.
If you intend to connect other devices to the POWER OUT
socket in a daisy chain, add together the maximum current
draw of all the devices in the chain. Do not create a chain of
devices whose total maximum current draw will exceed the
maximum current rating of any connector in the chain. The
maximum permitted current at the POWER IN connector is
16 A. The maximum permitted current at the POWER OUT
connector is 12 A.
The voltage and frequency at the POWER OUT socket are the
same as the voltage and frequency applied to the POWER IN
socket. Only connect devices to the POWER OUT socket that
accept this voltage and frequency.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (T
a
)
exceeds 40° C (104° F).
The surface of the product casing can reach up to 65° C
(149° F)
–
TBC during operation. Avoid contact by persons