Dry Seasoned Wood Only! 3-90-798 Save These Instructions
Oakleaf Woodburning stove
Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection)
Flue Liner with Re-
quired Air Space
Stainless Steel Chimney
Connector Must Extend
to Flue Liner
Minimum 8" Masonry
Thickness in Front of
Smoke Chamber
Use Damper Adapter or Seal with
Non-Combustible Material
*Floor Protection in Accordance with Solid Fuel Appliance Listing
Airtight
insulated
Clean-Out
Damper Plate is Removed
or Fastened in Open Posi-
tion
Listed Fireplace Trim
Protection for Re-
duced Clearance
Floor Protection*
Combustible Floor
The Chimney Connector shall Not Pass Through an Attic or Roof space, Closet
or similar Concealed space, a floor or Ceiling.
NOTICE: When using rear flue configuration, a
new upper rear heat shield, #1-00-797066 must be
installed in place of the existing shield.