Harman Home Heating OAKLEAF Скачать руководство пользователя страница 5

5

Save These Instructions                                                                  3-90-798                                                             Dry Seasoned Wood Only!

Oakleaf Woodburning stove

NEvER CONNECT THIs uNIT TO A CHIMNEy 

fLuE sERvING ANOTHER APPLIANCE.

Installation  and  repair  of  this  stove  should 

be  done  by  a  qualified  service  person.    We 

recommend  that  the  stove  be  inspected 

before use and at least annually by a qualified 

service person. Periodic cleaning is required 

throughout  the  heating  season  and  at  the 

end  of  each  winter  for  the  stove  to  work 

efficiently.  

sPECIAL NOTE: 

duE  TO  AsH  BuILduP,  IT  Is  sTRONGLy 

RECOMMENdEd  TO  HAvE  yOuR  sTOvE 

PROfEssIONALLy CLEANEd ANd sERvICEd 

ANNuALLy. THIs INCLudEs ALL PARTs Of 

THE  sTOvE, ANd  THE  vENTING  sysTEM.

Carbon monoxide, referred to as CO, is a colorless, odor-

less gas that is produced during combustion of wood and 

other fuels. 

CO fumes are toxic and can be fatal.

The Oakleaf is a natural draft system which relies on a 

properly designed chimney to remove CO and other com-

bustion by-products from the stove.

Even  though  this  stove  is  designed  to  be  as  safe  as 

possible, it is important that you 

install a CO detector.

 This 

is true for oil, gas, or coal burning products as well.

CO  is  not    specifically  heavier  or  lighter  than  air. 

Therefore, it is best to install the detector at table top level 

rather than on the ceiling like a smoke detector.

CO detectors are very sensitive and may  sound an alarm 

for fumes other than CO or CO from sources other than the 

stove such as car or lawn mower exhaust.

If the alarm sounds 

1. Increase ventilation by opening windows or doors.

2.  Make  sure  the  stove  doors  and  lid  are  closed  and 

latched.

3. Check stove for smoking or puffing condition. Open by-

pass and increase air-flow to firebox, if needed.

4. Check chimney for possible blockage or down-draft.

5. Check for false alarm.

Never use gasoline, lantern fuel, kerosene, charcoal 

lighter fluid, or similar liquids to start or “freshen 

up” a fire in this heater.  Keep all such liquids well 

away from the heater while it is in use.

2

 

special Warnings and Notes

dO NOT CONNECT TO ANy AIR 

dIsTRIBuTION duCT OR sysTEM.

If INsTALLING ON A COMBusTIBLE fLOOR, 

THE BOTTOM HEAT sHIELd MusT BE 

INsTALLEd ALONG WITH PROPER fLOOR 

PROTECTION MATERIAL.

Содержание OAKLEAF

Страница 1: ...Comply with all minimum clearances to combustibles as specified Failure to comply may cause a house fire Check building codes prior to installation Installation MUST comply with local regional state...

Страница 2: ...U SEULEMENT Cet appareil est galement homologu pour tre install dans un atelier VITEZ LES INCENDIES DE MAISON N installez et n utilisez cet appareil que selon le mode d installation et le mode d empl...

Страница 3: ...Mobile Home US only A Mobile Home Installation 21 Section 7 Appliance Set Up A Outside Air Attachment 22 B Leveling The Appliance 22 C Optional Cooking Grill 22 D Optional Blower Kit 23 E Optional Rea...

Страница 4: ...must be properly grounded to the frame of the mobile home and must never be installed in a room designated for sleep ing The unit must have provisions for an outside air source when installed in a mob...

Страница 5: ...is designed to be as safe as possible it is important that you install a CO detector This is true for oil gas or coal burning products as well CO is not specifically heavier or lighter than air There...

Страница 6: ...is needed to replace what the chimney draws away through the appliance CAUTION Do NOT connect this unit to a chimney flue servicing another appliance Do NOT connect to any forced air distribu tion duc...

Страница 7: ...Follow these instructions for changing the direction First remove the upper rear heat shield by removing 8 tek screws that secure it Reaching upward through the firebox and the open bypass damper loos...

Страница 8: ...le 12 The optional air distribution blower has been installed properly 13 A properly grounded electrical receptacle is available within reach of the blower s power cord if installed WARNING WARNING In...

Страница 9: ...1 1990 Weight 430 lbs Flue Size 6 inch Log Length Recommended 18 Average Emissions 2 2 Grams Per Hr Outside Air size 4 5 inch I D 25 635mm 26 2 665 5mm 27 2 691mm 29 2 742mm 18 9 480mm 25 6 650mm Air...

Страница 10: ...Pipe to Ceiling 16 407 mm F Minimum Vertical 0 0 mm For clearance reduction methods refer to NFPA 211 or Local Codes Pipe clearance may be reduced using double wall or insulated connector pipe provid...

Страница 11: ...Side Wall 17 432 mm B Unit to Back Wall 13 330 mm C Vent Pipe to Side Wall 26 5 673 mm Corner Installation D Shield Corner to Wall 14 356 mm E NFPA 211 specifies clearance of 18 457 mm Although vent c...

Страница 12: ...lue the better the protection Example 1 inch of Durock 0 52R In all installations the area under and around the stove must be protected from falling ash and live coals The area under a horizontal run...

Страница 13: ...or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible C Wall Pass thrus Depending on your local building codes...

Страница 14: ...neys extend 3 ft 0 9 m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot...

Страница 15: ...ferred method a breech pipe is a piece of steel pipe used the same way In Canada a breech pipe has ridges or protrusions to lock it firmly into the refractory cement In either case the chimney connect...

Страница 16: ...g Installation with Factory Built Chimney Chimney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Collar Chimney Connector Cathedral Ceiling Installation with Factory Built Chimney Roof...

Страница 17: ...per Joint of Chimney Connector Mantel and Trim Pro tection Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean out Chimney Breach Fireplace Conversion with Non Co...

Страница 18: ...Seal with Non Combustible Material Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean Out Damper Plate is Removed or Fastened in Open Posi tion Listed Fireplace...

Страница 19: ...ning system Follow liner manufacturer s instructions on insulation and support Floor Protection in Accordance with Solid Fuel Appliance Listing Damper Plate Removed or Fas tened in Open Position Floor...

Страница 20: ...rior Chimney or 2 Clearance for Interior Chimney and 2 Clear ance for NFPA 211 Type Approved Thimbles Floor Protection in Accordance with Solid Fuel Appliance Listing Check with your local building co...

Страница 21: ...vent manufacturer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manu factured Home and Safety Standard HUD CFR 3280 Part 24 8 The appliance must never...

Страница 22: ...ke flex pipe into the stub on the rear of the Oakleaf and secure it with aluminum tape This air intake will supply outside air for the secondary combustion within the FireDome 7 Secure the trim ring i...

Страница 23: ...rom the top vent shield and install the rear vent shield in it s place Height adjustment for blower use is done the same as with the top vent shield in place See D Optional Blower Installation above f...

Страница 24: ...d interfere with door operation safe loading and ash removal B General Operating Information 1 Draft Before you install and operate your Oakleaf wood stove please read the entire contents of this manu...

Страница 25: ...is where the volatile gases contained in the wood are released and burned This represents most of the wood s heating capacity The final stage is the charcoal stage where the charcoal burns the remaini...

Страница 26: ...imum air flow Ignite the paper and close the loading door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 8...

Страница 27: ...imary air control lever too far to the right 3 Inadvertently leaving the damper open or 4 Not keeping up with routine maintenance such as checking door gaskets for wear Overfiring results in excessive...

Страница 28: ...ling During future burns be careful not to overload the stove with fuel so you will not be tempted to constantly operate at a low air control setting Other causes of poor ventilation or draft are icin...

Страница 29: ...or yard waste 2 Door Glass Frequency As needed Weekly By User Whenever the view of the fire is obstructed or weekly clean the glass using a soft cloth dampened with stan dard household glass cleaner...

Страница 30: ...s very important to clean all ashes at the end of the heating season When cleaning the chimney connector above the ap pliance keep the bypass damper in the open position This will keep any loosened ma...

Страница 31: ...Dry Seasoned Wood Only Oakleaf Woodburning Stove 10Reference Materials Variable Speed Switch Power Cord Blower Thermostat Rocker Grounded to housing Switch Black Wire White Wire 2 1 Oakleaf Optional B...

Страница 32: ...ollowing page Cast Iron Wood stove 1 90 797000 1 Black 1 90 797000 2 Charcoal 1 90 797000 3 Goldenfire Beginning Manufacturing date sept 2010 Ending Manufacturing date Active 1 2 7 6 8 23 22 3 4 5 28...

Страница 33: ...Round PSA 15 FT 1 00 2312 y 9 Brick Clip Set 1 00 249153 y 10 Damper Assembly 1 10 797103A y Damper Adjustment Kit 1 00 249142 y Damper Handle 3 50 00500S y Damper Plate 4 00 797113 y Damper Rod 1 10...

Страница 34: ...Nut FHN 5 16 18 Z 5 Pkg of 100 3 30 8005 100 y 21 Center Brick 3 40 797020 y Gasket 1 4 Round PSA 15 FT 1 00 2312 y 22 Brick 12 X 6 X 1 1 4 3 40 86125 y Brick Clip 1 Set 1 00 249172 y 23 Seal Plate 1...

Страница 35: ...after July 1 1990 0 8 5 Grams Per Hour SMOke 50 60 70 80 90 100 Wood heaters with higher efficiencies cost less to operate effIcIency Heat OutPut 9 600 to 24 700 btu use this to choose the right size...

Страница 36: ...truction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlie...

Страница 37: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Страница 38: ...38 Dry Seasoned Wood Only 3 90 798 Save These Instructions Oakleaf Woodburning Stove Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 39: ......

Страница 40: ...Proudly Printed On 100 Recycled Paper...

Отзывы: