Dry Seasoned Wood Only! 3-90-798 Save These Instructions
Oakleaf Woodburning stove
Chimney Breach Fireplace Conversion with Combustible Wall
Minimum Clearance from
Chimney Connector to Un-
protected Ceiling
Flue Liner with Required Air Space
Listed or Approved Thimble Assembly
1" Clearance for Complex-
ity Exterior Chimney
or
2" Clearance for Interior
Chimney and 2" Clear-
ance for NFPA 211-Type
Approved Thimbles
* Floor Protection in Accordance with Solid Fuel Appliance Listing
** Check with your local building codes for clearance.
Combustible
Wall
Sheetrock
Airtight
insulated
Clean-out
Combustible Floor
Damper Closed and
Sealed with Non-
Combustible
Material.
Mantel & Trim
Protection
Floor Protection*
16"**
The Chimney Connector shall Not Pass Through an Attic or Roof space, Closet
or similar Concealed space, a floor or Ceiling.