23
venting
Fig. 50
This method provides excellent venting for nor-
mal operation. This method also provides natural
draft in the event of a power failure.
The damper area must be sealed with a steel
plate. A cap should be installed on the chimney to
keep out rain.
Combustion air is provided from the living area
and enters the feed system from around the wing and
stove body spaces.
#2 Installing into an existing
fireplace chimney
This method provides excellent venting with
100% outside air which is the most efficient opera-
tion of this unit. This method also provides natural
draft in the event of a power failure.
A 4 inch stainless steel flex pipe is needed for
the flue pipe, and 3" aluminum or Stainless Steel
Flex Pipe is used for the intake.
#1 Installing into an existing fireplace
chimney
Fig. 49
Height of existing hearth
The chimney top must be capped
to prevent rain and/or snow from
entering the chimney.
See Page 22. for information on
the optional Harman Adjustable
Stainless Steel Intake Exten-
sion.
The chimney top must be
capped to prevent rain and/or
snow from entering the chim-
ney.
The damper area must be
sealed with a steel plate and it
is recommended that Kaowool,
Mineral wool or an equivalent non
combustible insulation is used on
top of the plate to reduce the pos-
sibility of condensation. Insulation
alone should not be used to seal
the damper opening.
The damper area must be
sealed with a steel plate and it
is recommended that Kaowool,
Mineral wool or an equivalent non
combustible insulation is used on
top of the plate to reduce the pos-
sibility of condensation. Insulation
alone should not be used to seal
the damper opening.
wArNINg
ChImNEY CONNECTOr PIPE mAY NOT
PASS ThrOugh CONCEAlEd SPACES
INCludINg AN ATTIC, rOOF SPACE,
ClOSET, FlOOr Or CEIlINg.
Содержание Harman Accentra Insert
Страница 36: ......
Страница 37: ......
Страница 44: ...44 Service Maintenance Log Date Of Service Performed By Description Of Service...
Страница 47: ......
Страница 48: ...Proudly Printed On 100 Recycled Paper...