26/01/22 ENGLISH
21
The following table shows the theoretical deflection arrow as a function of the static load and of the distance
between the anchoring brackets in case of installation from 0° to 5°.
Furthermore, in order to evaluate the system fall clearance correctly, the following table shows the maximum
deflection measured during the dynamic and integrity resistance test, carried out in compliance with Standard
EN 795:2012 (paragraph 4.4.4.2) and Standard CEN/TS 16415:2013 (paragraph 4.2.5.1). For installations from
0° to 5° the test carried out with the weakest configuration - single span with 3 m distance to the INLKNK.LS
juncture at the centre of the span - is shown below. The brackets used to fasten the rail to the structure are the
INBRKT.3 stainless steel brackets. The test has been carried out near the joint at the centre of the span.
Furthermore, in order to correctly define the distance between the brackets, it is necessary to evaluate the
resistance of the structure to which it is fastened.
WARNING!
An incorrectly fastened system may not guarantee the adequate resistance to a fall, with consequent
grave risks and danger of fatal injuries.
VERTICAL
HORIZONTAL
X
X
Y
Y
LOAD DIRECTION
LOAD APPLIED IN THE HORIZONTAL DIRECTION
Span/Load
1000 [N]
2000 [N]
3000 [N]
4000 [N]
[mm]
[mm]
[mm]
[mm]
[mm]
500
0,11
0,21
0,32
0,43
750
0,36
0,72
1,09
1,45
1000
0,86
1,71
2,57
3,43
1250
1,67
3,35
5,02
6,70
1500
2,89
5,79
8,68
11,58
1750
4,60
9,19
13,79
18,38
2000
6,86
13,72
20,58
27,44
2250
9,77
19,53
29,30
39,07
2500
13,40
26,80
40,19
53,59
2750
17,83
35,67
53,50
71,33
3000
23,15
46,30
69,46
92,61
LOAD APPLIED IN THE HORIZONTAL DIRECTION
Span/Load
1 persona
2 persone
3 persone
4 persone
[mm]
[mm]
[mm]
[mm]
[mm]
3000
370
380
395
410
LOAD APPLIED IN THE VERTICAL DIRECTION
Span/Load
1000 [N]
2000 [N]
3000 [N]
4000 [N]
[mm]
[mm]
[mm]
[mm]
[mm]
500
0,16
0,32
0,49
0,65
750
0,55
1,10
1,64
2,19
1000
1,30
2,60
3,90
5,20
1250
2,54
5,08
7,61
10,15
1500
4,39
8,77
13,16
17,54
1750
6,96
13,93
20,89
27,86
2000
10,40
20,79
31,19
41,58
2250
14,80
29,60
44,40
59,21
2500
20,30
40,61
60,91
81,21
2750
27,02
54,05
81,07
108,10
3000
35,08
70,17
105,25
140,34
LOAD APPLIED IN THE VERTICAL DIRECTION
Span/Load
1 persona
2 persone
3 persone
4 persone
[mm]
[mm]
[mm]
[mm]
[mm]
3000
405
410
430
455
Distance between the brackets = distance between
the centerline of
two adjacent
brackets
Содержание R27LS
Страница 2: ......
Страница 53: ...26 01 22 ENGLISH 53 INBRKT X5 INBRKT X6...
Страница 57: ...26 01 22 ENGLISH 57 INMID ENTRY1 LS 60 60 160 400 116 5 116 5 0 5 0 5 43 2 INMID ENTRY1 LS...
Страница 58: ...58 ENGLISH 26 01 22 INMID ENTRY3 LS 400 116 5 116 5 58 86 28 31 INMID ENTRY3 LS...
Страница 66: ...66 ENGLISH 26 01 22 326 326 412 412 49 INTURN1 LS...
Страница 67: ...26 01 22 ENGLISH 67 326 652 412 49 INTURN2 LS...
Страница 73: ...26 01 22 ENGLISH 73 250mm INLINK LS INLINK LS INSTOP LS INSTOP LS 10 1 cm L6...
Страница 74: ...74 ENGLISH 26 01 22 250mm INLINK LS INLINK LS INSTOP LS INSTOP LS 10 1 cm L7...
Страница 85: ...26 01 22 ENGLISH 85 INMID ENTRY1 LS INSTALLATION Gap 1 5mm Gap 1 5mm INR27 LS INR27 LS 339mm 120mm L18...