8 - Technical specifications
104
Pump Model 463/12.0
Technical Residue
Residue in the dilutable volume is mentioned in the table below.
The non-dilutable volume varies depending on the boom width and installed options in the fluid system.
Filters and Nozzles
Possible options:
*depending on selected nozzles
**not with PrimeFlow system
Temperature and Pressure Ranges
Sprayer combination
Dilutable volume for tank and fluid system
Main tank: 4000 litres
Boom width: 28 meters
41 litres
Filter name
Mesh
Gauze width
Color
EasyClean
Cyclone
In-line**
Tank strainer
Nozzle
18
1.00 mm
White
-
-
-
Yes
-
30
0.60 mm
Green
Yes
-
-
-
-
50
0.30 mm
Blue
Yes, standard
-
Yes*
-
Yes*
80
0.18 mm
Red
Yes
Yes, standard
Yes*
-
Yes*
100
0.15 mm
Yellow
-
-
Yes*
-
Yes*
Spray liquid system
Operating temperature range
2 - 40 °C
Operating pressure for the safety valve
15 bar
Max. pressure on the pressure manifold
20 bar
Max. pressure on the suction manifold
1.5 bar
Hydraulic system
Max. operating temperature
75 °C
Operating pressure from the tractor
190 - 210 bar