![Hardi Mercury Covamax series Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/hardi/mercury-covamax-series/mercury-covamax-series_operators-instruction-manual_3929961056.webp)
5 - Operation
5. 2
Adjusting Pressure equalisation
Pressure equalisation on machines fitted with HARDI EVC or
Braglia CB/2 control units are adjusted using these steps;
•
With the boom section valves open, run the sprayer at normal
average spraying pressure.
•
Note the reading on the pressure gauge (B)
•
Close the first section valve (1) by turning off at the
switchbox.
•
When system pressure has stabilised, adjust the first
equalisation valve (A) until the original spraying pressure is
restored, then reopen the valve at switchbox.
•
Repeat the procedure until both valves have been balanced.
μ
Attention: After service procedures it is recommended to re-
calibrate equipment before spraying. The equalisation procedure
is generally only required after servicing, changing nozzle size or
when compensating for worn nozzles.
Содержание Mercury Covamax series
Страница 1: ...MERCURY COVAMAX Operator Instruction Manual 67002404 100 HAU 08 2009 www hardi com au...
Страница 10: ...Table of Contents TOC 8...
Страница 18: ...2 Safety 2 6...
Страница 88: ...6 Maintenance 1 18 Maintenance Activity Record Date Service Performed...
Страница 92: ...7 Fault Finding 1 4...
Страница 95: ...8 Technical Specifications 8 3 50 mesh 0 30 mm BLUE 80 mesh 0 18 mm RED 100 mesh 0 15 mm YELLOW...
Страница 100: ...8 Technical Specifications 8 8...