16
GB 05 06 06
Sprayer setup
Load Sensing
Please consult your tractor dealer for correct setup and
correct connection.
Certain tractor models are able to use Load Sensing
without
connecting an external sensing line (setting 1 in
scheme). But if optimal sensing control pressure
cannot
be obtained, an external sensing line needs to be
mounted (setting 2 in scheme).
Requirements - Load Sensing hose:
1/4 Standard hose
Max. rated working pressure = 200 bar.
IMPORTANT!
It is of essential importance that connec-
tors on sensing line are kept totally clean. Failure to do
so will cause impurities entering the pump and thereby
cause damages to vital pump parts.
029
c
il
u
a
r
d
y
h
/r
o
t
c
a
r
T
m
e
t
s
y
s
e
v
l
a
v
e
g
d
ir
t
r
a
C
r
o
t
a
l
u
g
e
r
w
o
l
F
d
r
a
d
n
a
t
S
)
r
o
t
c
a
rt
w
o
lf
t
n
a
t
s
n
o
c
(
n
e
p
O
n
e
p
O
e
r
t
n
e
c
d
e
s
o
l
C
)
s
r
o
t
c
a
rt
D
J
n
i
a
tr
e
c
(
d
e
s
o
l
C
d
e
s
o
l
C
g
n
i
s
n
e
s
d
a
o
L
.
1
t
u
o
h
ti
W
l
a
n
r
e
t
x
e
e
n
il
g
n
i
s
n
e
s
n
e
p
O
n
e
p
O
g
n
i
s
n
e
s
d
a
o
L
.
2
h
ti
W
l
a
n
r
e
t
x
e
e
n
il
g
n
i
s
n
e
s
d
e
s
o
l
C
n
e
p
O
Valve open
Valve closed
T112-0004x
Flow regulator
Cartridge valve
T112-0004x
LS
Connect hose to
LS on the
distribution block
T112-0007x
Hy
Hy
Hy
Hy
Hydr
dr
dr
dr
draulic sy
aulic sy
aulic sy
aulic sy
aulic systems
stems
stems
stems
stems
Hy
Hy
Hy
Hy
Hydr
dr
dr
dr
draulics COMMANDER-HA
aulics COMMANDER-HA
aulics COMMANDER-HA
aulics COMMANDER-HA
aulics COMMANDER-HAY
YY
YY
Tractor Operated Hydraulics
Connection requirements for COMMANDER-HAY are
one double acting and one single acting spool valve.
Single acting valve
: Boom lift, up/down
Double acting valve
: Boom folding and unfolding
Ensure the snap couplers are clean before connection!
If hydraulic slanting control is fitted another double acting
spool valve on the tractor is required.
NOTE!
The hydraulic system requires a minimum oil
pressure of 130 bar, max. oil pressure of 210 bar and an
oil capacity of approx. 5 litres. After having operated the
boom and the system has been filled with oil, check
tractors hydraulic oil level and top up if necessary.
Hy
Hy
Hy
Hy
Hydr
dr
dr
dr
draulics COMMANDER-HAZ
aulics COMMANDER-HAZ
aulics COMMANDER-HAZ
aulics COMMANDER-HAZ
aulics COMMANDER-HAZ
Direct Acting Hydraulic system
The D.A.H. system requires a double acting hydraulic
outlet. The hydraulic hoses are marked with arrows to
indicate direction of oil flow.
The D.A.H. system requires an oil flow between 10 and
90 l/min (19.8 Imp. gal/min.) and a min. pressure of 130
bar (1886 p.s.i.) The system has a built-in flow regulator
that maintains constant speed on hydraulic movements.
The hydraulic distribution block is situated underneath
the platform floor.
The valves on the block are operated by means of
manual override and each valve can be regulated to be
open or closed.
Before operating the hydraulics, the valves on the
sprayers hydraulic distribution block should be adjusted
according to the specific tractor model (please refer to
scheme later in this part).
If you have doubt about which type of hydraulic system
your tractor is equipped with, please ask your tractor
dealer.