21
Mistblower and HP 3570
Points to note if the system is used on a mistblower.
• Work width is the same as the spray width of the mistblower.
• Use the Tank method to calibrate the flow transducer. See “Menu,
[
0 2
0 2
] Flow calibration - Tank method.”
• Blower fan revolutions can be read if the gear ratio is know. See
“Menu, [
0 7
0 7
] Revolutions readout of P.T.O.”
Storage
When not in use, disconnect the power supply. This will stop the
system from using power.
The display should be protected from moisture and should be removed
if the tractor does not have a cabin.
Fault finding
Error codes during start-up
At start-up, the following error codes may be shown:
[
L I N E F A I L
L I N E F A I L
] This indicates that the unit can “see” signals on
HARDI LINK, but cannot interpret them.
Action:
Check the system is correctly terminated. See
“Menu, [
1 1
1 1
] HARDI LINK”. When this check is
finished, re-start the system.
[
N o d a t a
N o d a t a
]
This means that there is no signal on HARDI LINK.
Action:
Check all the coaxial cable connections as well as
the termination in the display See “Menu, [
1 1
1 1
]
HARDI LINK” and then re-start the system.
[
N O S A V E
N O S A V E
] This error indicates that the modified parameters in
the set-up have not been saved in the display
memory.
Action:
Check whether the function selected is accessible.
[
≡≡ ≡≡ ≡≡ ≡≡
]
If the value 9999 is exceeded, the display will indicate
this with 12 horizontal dashes (overflow).