For technical questions, please call 1-888-866-5797.

ITEM 59134 

        

SAFETY

SETU
p

Op
ERA
TION

M

AINTENANCE

10. Fire Hazard! Do not fill gas tank while engine is 

running.  Do not operate if gasoline has been spilled.  

Clean spilled gasoline before starting engine. 

Do not operate near pilot light or open flame.

11.  If the plugged-in product operates abnormally 

or unusually slow, immediately stop using the 

Generator as a power source.  Always read and 

adhere to the instruction manual of the product 

to be powered, to make sure that it can be safely 

and efficiently powered by a portable generator.  

12. Before connecting an appliance or power cord 

to the Generator:  Make sure that it is in good 

working order.  Faulty appliances or power cords 

can create a potential for electrical shock.

13. Do not exceed the maximum power rating of the 

Generator.  Make sure that the total electrical rating 

of the all of the tools or appliances plugged into 

the Generator at the same time does not exceed 

that of the Generator.  Check that the startup 

surge will not be beyond the limit of the Generator.  

Power levels between rated and maximum 

may be used for no more than 30 minutes.

14. Avoid substantially overloading which will 

trip the circuit breaker.  Exceeding the time 

limit for maximum power operation or slightly 

overloading the Generator may not switch the 

circuit breaker or circuit protector OFF, but will 

shorten the service life of the Generator.

15. Do not attempt to connect or disconnect 

load connections while standing in 

water, or on wet or soggy ground.

16. Do not touch electrically energized parts of 

the Generator and interconnecting cables 

or conductors with any part of the body, or 

with any non-insulated conductive object.

17. Connect the Generator only to a load or 

electrical system (120 volt or 240 volt) that is 

compatible with the electrical characteristics 

and rated capacities of the Generator.

18. 

GFCI pRECAUTIONS 

Test Ground Fault Circuit Interrupter (GFCI) 

receptacles before each use as follows:

a.  Disconnect all devices from the Generator.
b.  Start the engine.
c.  Press Test button on receptacle 

to trip the GFCI device.

d.  The Reset button should extend, cutting 

off electricity to the receptacle.

e.  If above test fails, do not use receptacle 

until it is repaired or replaced.

f.  Press Reset button in for use.

The Generator must be grounded before use.   

An ungrounded Generator has an 

increased risk of electric shock.  

Refer 

to 

Grounding

 on page 9.

19. Insulate all connections and disconnected wires.
20. Guard against electric shock.  Prevent body 

contact with grounded surfaces such as 

pipes, radiators, ranges, and refrigerators.

21. Only use a suitable means of transport and 

lifting devices with sufficient weight bearing 

capacity when transporting the Generator.

22. Secure the Generator on transport vehicles to 

prevent the tool from rolling, slipping, and tilting.

23. Industrial applications must follow 

OSHA requirements.

24. Do not leave the Generator unattended when it is 

running.  Turn off the Generator (and remove safety 

keys, if available) before leaving the work area.

25. The Generator engine can produce high noise 

levels.  Prolonged exposure to noise levels 

above 85 dBA is hazardous to hearing.  Always 

wear ear protection when operating or working 

around the gas engine while it is operating.

26. Wear ANSI-approved safety glasses, 

hearing protection, and NIOSH-approved 

dust mask/respirator during use.

27. People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields 

in close proximity to a heart pacemaker could 

cause pacemaker interference or pacemaker 

failure.  Caution is necessary when near 

the engine’s magneto or recoil starter.

28. Use only accessories that are recommended 

by Harbor Freight Tools for your model.  

Accessories that may be suitable for one 

piece of equipment may become hazardous 

when used on another piece of equipment.

29. Do not operate in explosive atmospheres, 

such as in the presence of flammable 

liquids, gases, or dust.  Gasoline-powered 

engines may ignite the dust or fumes.

30. Keep grounded conductive objects, such as 

tools, away from exposed, live electrical parts 

and connections to avoid sparking or arcing.  

These events could ignite fumes or vapors.

31. Stay alert, watch what you are doing and 

use common sense when operating this 

piece of equipment.  Do not use this piece 

of equipment while tired or under the 

influence of drugs, alcohol or medication.

32. Dress properly.  Do not wear loose clothing or 

jewelry.  Keep hair, clothing and gloves away 

from moving parts.  Loose clothes, jewelry or 

long hair can be caught in moving parts.

33. Parts, especially exhaust system components, 

get very hot during use.  Stay clear of hot parts.

34. Do not cover the Generator or its 

engine during operation.

Содержание PREDATOR 59134

Страница 1: ...ence 22f Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 a...

Страница 2: ...aken Access shall be through the use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 3 Have multiple ABC class fire extinguishers nearby 4 Operation ...

Страница 3: ...allow carbon monoxide to accumulate FLASHING RED LIGHT Dangerous levels of carbon monoxide gas have built up and generator will shutoff Leave immediately until area has aired out Move Generator to well ventilated area before operation FLASHING YELLOW LIGHT Carbon monoxide sensor malfunction Sensor needs service Do not use the Generator until the sensor is working properly For technical questions p...

Страница 4: ...eplaced f Press Reset button in for use The Generator must be grounded before use An ungrounded Generator has an increased risk of electric shock Refer to Grounding on page 9 19 Insulate all connections and disconnected wires 20 Guard against electric shock Prevent body contact with grounded surfaces such as pipes radiators ranges and refrigerators 21 Only use a suitable means of transport and lif...

Страница 5: ...f moving parts breakage of parts and any other condition that may affect the Generator s operation If damaged have the Generator serviced before using Many accidents are caused by poorly maintained equipment 42 Use the correct generator for the application Do not modify the generator or its engine and do not use the generator for a purpose for which it is not intended 43 Extension Cord Make sure y...

Страница 6: ...orrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI Protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit interrupter GFCI receptacles These outlets provide additional protection from the risk of electric shock Should replacement of the receptacles become necessary use only identical replacement parts t...

Страница 7: ...oline Capacity 7 79 Gallon 29 50 Liter Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 Quart Spark Plug Type NHSP Torch F6TC Gap 0 028 0 031 Valve Clearance Intake 0 004 0 006 Exhaust 0 004 0 006 Run Time 50 load Up to 13 hr Available accessories Wheel kit sold separately The emission control system for this Generator s Engine is warranted for standards set by the U S Envir...

Страница 8: ...eptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used ON OFF 3 Circuit Breakers The circuit breaker protects the Generator from overloading The rating of the breaker and the load it protects are marked near the breaker Should any of the Circuit Breakers trip the Generator will stop the electricity output If th...

Страница 9: ... intended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector both not included Sensitive electronic equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators Wheel Kit 64...

Страница 10: ...ons are as follows Use one of the following as the grounding electrode Pipe or conduit minimum in diameter minimum 8 ft long If steel it must have anti corrosion coating Rod stainless steel or copper or zinc coated steel minimum 5 8 in diameter minimum 8 ft long 1 Drive electrode at least 8 ft vertically into the ground a If rock layer prevents vertical entry drive at an angle not exceeding 45 deg...

Страница 11: ...owl under the fuel cup to catch any spilled fuel 5 Unthread the screws holding the solenoid in place CAUTION Carburetor bowl may have gas in it which will leak upon removing the solenoid bolt 6 Disconnect the solenoid and solenoid seal from the bolt 7 Unthread the bolt holding the fuel cup 8 Remove the bolt Bolt Seal fuel cup Fuel Cup Seal and Main Jet from the body of the carburetor assembly A ca...

Страница 12: ...hout threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use The SAE Viscosity Grade chart on page in the Service section shows other viscosities to use in different average t...

Страница 13: ... If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5 When finished using the Generator disconnect all electrical loads Note Do not allow Generator to run out of fuel with loads attached 6 Turn off the Engine 7 Allow the Generator and its Engine to comp...

Страница 14: ...at the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle sna...

Страница 15: ...e rated capacity for this Generator as serious damage to the Generator and or appliances tools and equipment could result from an overload Starting and running wattage requirements should always be calculated when matching this Generator s wattage capacity to the appliance tool or equipment Use the DC12V Receptacle to power 12VDC equipment WARNING TO PREVENT SERIOUS INJURY Do not charge batteries ...

Страница 16: ...or that only supplies the exact watts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate of additional Start up Watts For most lights or heaters there are no additional start up watts Wattage Estimate Charts Note Watta...

Страница 17: ...ngine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off the Engine turn off all electrical loads then unplug them 2 Turn the Engine Switch off 3 Close the Fuel Valve I O START OFF RESET TEST RESET TEST I O START OFF ...

Страница 18: ...a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems immediately The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle temperature air quality fuel quality and other factors...

Страница 19: ... Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around it Remove the Dipstick by threading it counterclockwise and wipe it off with a clean lint free rag 7 Full Level Full Level Add the appropriate type of oil until the oil level is at the full level SA...

Страница 20: ...or back in place immediately after cleaning and before further operation Long Term Storage When the equipment is to remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water can cause rust damage over time Apply a thin coat of rust preventive oil to all metal parts 2 FU...

Страница 21: ...exposure to rain and sunlight NOTICE During extended storage periods the Engine must be started every 3 months and allowed to run for 15 20 minutes or the Warranty is VOID 6 AFTER STORAGE Before starting the Engine during or after storage keep in mind that untreated gasoline will deteriorate quickly Drain the fuel tank and change to fresh fuel if untreated gasoline has been sitting for a month if ...

Страница 22: ...Filter IGNITION SPARK RELATED 1 Power Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet or dirty 4 Incorrect spark plug gap 5 Spark plug cap broken 6 Circuit breaker tripped electric start models only 7 Incorrect spark timing or faulty ignition system IGNITION SPARK RELATED 1 Turn Power Switch to ON 2 Connect spark plug cap properly 3 Clean spark plug 4 Corr...

Страница 23: ...ly operate generator outside 2 Carbon monoxide sensor malfunction Sensor needs service Call 1 888 866 5797 as soon as possible Do not use the Generator until the sensor is working properly 3 Make sure to operate generator within rated ambient temperature maintain minimum 5 ft clearance from all sides 4 Fill engine oil to proper level Check engine oil before EVERY use 5 Fill fuel tank with fresh 87...

Страница 24: ...ker Plug in product and turn on 3 Turn off and unplug product Test GFCI receptacle If functioning properly reset GFCI plug in product and turn on 4 Have product repaired Product begins to operate abnormally 1 Problem with appliance 2 Rated load capacity exceeded 1 Immediately unplug appliance Have appliance repaired by a qualified technician or replace appliance 2 Lower the number of items plugged...