background image

Page 19

For technical questions, please call 1-888-866-5797.

ITEM 59134 

        

SAFETY

SETU

p

Op

ERA

TION

M

AINTENANCE

Checking and Filling Fuel

WARNING!

 

TO pREVENT SERIOUS 

INJURY FROM FIRE:

 

Fill tank in a well-ventilated area away 

from ignition sources.  If the engine 

is hot from use, shut the engine off and 

wait for it to cool before adding fuel.  Do not smoke.

1.  Clean the Fuel Cap and the area around it.

2.  Unscrew and remove the Fuel Cap.

Note:

 

Do not use gasoline containing more than 

10% ethanol (E10).  Do not use E85 ethanol.

Note:  Do not use gasoline that has been stored in a 

metal fuel container or a dirty fuel container.  It can 

cause particles to enter the carburetor, effecting 

engine performance and/or causing damage.

3.  If needed, fill the Fuel Tank to about 1 inch 

under the fill neck with 87 octane or higher 

unleaded gasoline that has been treated with 

a fuel stabilizer additive.  Follow fuel stabilizer 

manufacturer’s recommendations for use.

4.  Replace the Fuel Cap.

5.  Wipe up any spilled fuel and allow excess 

to evaporate before starting engine.  

To prevent FIRE, do not start the engine 

while the smell of fuel hangs in the air.

Engine Oil Change

CAUTION!

  Oil is very hot during operation and can 

cause burns.  Wait for engine to cool before changing oil.

1.  Make sure the engine is stopped and is level.

2.  Close the Fuel Valve.

3.  Place a drain pan (not included) underneath 

the crankcase’s drain plug.

4.  Remove the drain plug and, if possible, 

tilt the crankcase slightly to help drain 

the oil out.  Recycle used oil.

5.  Replace the drain plug and tighten it.

6.  Clean the top of the Dipstick and the area around it.  

Remove the Dipstick by threading it counterclockwise, 

and wipe it off with a clean lint free rag.

7. 

Full Level

Full Level

Add the appropriate type of oil until the  

oil level is at the full level.  SAE 10W-30 

oil is recommended for general use. 

Note:

 Do not thread the dipstick in 

when checking the oil level.

The SAE Viscosity Grade chart shows other 

viscosities to use in different average temperatures.

10W-30

30

5W-30

-20

0

20

40

60

80

100°F

SAE Viscosity Grades

Average outdoor temperature

8.  Thread the dipstick back in clockwise.

NOTICE:  Do not run the engine with too little oil.  

Engine will not start with low or no engine oil.

Air Filter Element Maintenance

1.  Remove the air filter cover and the air filter elements 

and check for dirt. Clean as described below.

2. 

Cleaning:

•  For “paper” filter elements: 

To prevent injury from dust and debris, wear 

ANSI-approved safety goggles, NIOSH-approved 

dust mask/respirator, and heavy-duty work gloves.  

In a well-ventilated area away from bystanders, 

use pressurized air to blow dust out of the air filter. 

If this does not get the filter clean, replace it.

•  For foam filter elements: 

Wash the element in warm water and mild 

detergent several times. Rinse. Squeeze out 

excess water and allow it to dry completely.  

Soak the filter in lightweight oil briefly, 

then squeeze out the excess oil.

3.  Install the cleaned filter.  Secure the 

Air Cleaner Cover before use.

Содержание PREDATOR 59134

Страница 1: ...ence 22f Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 a...

Страница 2: ...aken Access shall be through the use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 3 Have multiple ABC class fire extinguishers nearby 4 Operation ...

Страница 3: ...allow carbon monoxide to accumulate FLASHING RED LIGHT Dangerous levels of carbon monoxide gas have built up and generator will shutoff Leave immediately until area has aired out Move Generator to well ventilated area before operation FLASHING YELLOW LIGHT Carbon monoxide sensor malfunction Sensor needs service Do not use the Generator until the sensor is working properly For technical questions p...

Страница 4: ...eplaced f Press Reset button in for use The Generator must be grounded before use An ungrounded Generator has an increased risk of electric shock Refer to Grounding on page 9 19 Insulate all connections and disconnected wires 20 Guard against electric shock Prevent body contact with grounded surfaces such as pipes radiators ranges and refrigerators 21 Only use a suitable means of transport and lif...

Страница 5: ...f moving parts breakage of parts and any other condition that may affect the Generator s operation If damaged have the Generator serviced before using Many accidents are caused by poorly maintained equipment 42 Use the correct generator for the application Do not modify the generator or its engine and do not use the generator for a purpose for which it is not intended 43 Extension Cord Make sure y...

Страница 6: ...orrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI Protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit interrupter GFCI receptacles These outlets provide additional protection from the risk of electric shock Should replacement of the receptacles become necessary use only identical replacement parts t...

Страница 7: ...oline Capacity 7 79 Gallon 29 50 Liter Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 Quart Spark Plug Type NHSP Torch F6TC Gap 0 028 0 031 Valve Clearance Intake 0 004 0 006 Exhaust 0 004 0 006 Run Time 50 load Up to 13 hr Available accessories Wheel kit sold separately The emission control system for this Generator s Engine is warranted for standards set by the U S Envir...

Страница 8: ...eptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used ON OFF 3 Circuit Breakers The circuit breaker protects the Generator from overloading The rating of the breaker and the load it protects are marked near the breaker Should any of the Circuit Breakers trip the Generator will stop the electricity output If th...

Страница 9: ... intended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector both not included Sensitive electronic equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators Wheel Kit 64...

Страница 10: ...ons are as follows Use one of the following as the grounding electrode Pipe or conduit minimum in diameter minimum 8 ft long If steel it must have anti corrosion coating Rod stainless steel or copper or zinc coated steel minimum 5 8 in diameter minimum 8 ft long 1 Drive electrode at least 8 ft vertically into the ground a If rock layer prevents vertical entry drive at an angle not exceeding 45 deg...

Страница 11: ...owl under the fuel cup to catch any spilled fuel 5 Unthread the screws holding the solenoid in place CAUTION Carburetor bowl may have gas in it which will leak upon removing the solenoid bolt 6 Disconnect the solenoid and solenoid seal from the bolt 7 Unthread the bolt holding the fuel cup 8 Remove the bolt Bolt Seal fuel cup Fuel Cup Seal and Main Jet from the body of the carburetor assembly A ca...

Страница 12: ...hout threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use The SAE Viscosity Grade chart on page in the Service section shows other viscosities to use in different average t...

Страница 13: ... If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5 When finished using the Generator disconnect all electrical loads Note Do not allow Generator to run out of fuel with loads attached 6 Turn off the Engine 7 Allow the Generator and its Engine to comp...

Страница 14: ...at the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle sna...

Страница 15: ...e rated capacity for this Generator as serious damage to the Generator and or appliances tools and equipment could result from an overload Starting and running wattage requirements should always be calculated when matching this Generator s wattage capacity to the appliance tool or equipment Use the DC12V Receptacle to power 12VDC equipment WARNING TO PREVENT SERIOUS INJURY Do not charge batteries ...

Страница 16: ...or that only supplies the exact watts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate of additional Start up Watts For most lights or heaters there are no additional start up watts Wattage Estimate Charts Note Watta...

Страница 17: ...ngine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off the Engine turn off all electrical loads then unplug them 2 Turn the Engine Switch off 3 Close the Fuel Valve I O START OFF RESET TEST RESET TEST I O START OFF ...

Страница 18: ...a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems immediately The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle temperature air quality fuel quality and other factors...

Страница 19: ... Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around it Remove the Dipstick by threading it counterclockwise and wipe it off with a clean lint free rag 7 Full Level Full Level Add the appropriate type of oil until the oil level is at the full level SA...

Страница 20: ...or back in place immediately after cleaning and before further operation Long Term Storage When the equipment is to remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water can cause rust damage over time Apply a thin coat of rust preventive oil to all metal parts 2 FU...

Страница 21: ...exposure to rain and sunlight NOTICE During extended storage periods the Engine must be started every 3 months and allowed to run for 15 20 minutes or the Warranty is VOID 6 AFTER STORAGE Before starting the Engine during or after storage keep in mind that untreated gasoline will deteriorate quickly Drain the fuel tank and change to fresh fuel if untreated gasoline has been sitting for a month if ...

Страница 22: ...Filter IGNITION SPARK RELATED 1 Power Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet or dirty 4 Incorrect spark plug gap 5 Spark plug cap broken 6 Circuit breaker tripped electric start models only 7 Incorrect spark timing or faulty ignition system IGNITION SPARK RELATED 1 Turn Power Switch to ON 2 Connect spark plug cap properly 3 Clean spark plug 4 Corr...

Страница 23: ...ly operate generator outside 2 Carbon monoxide sensor malfunction Sensor needs service Call 1 888 866 5797 as soon as possible Do not use the Generator until the sensor is working properly 3 Make sure to operate generator within rated ambient temperature maintain minimum 5 ft clearance from all sides 4 Fill engine oil to proper level Check engine oil before EVERY use 5 Fill fuel tank with fresh 87...

Страница 24: ...ker Plug in product and turn on 3 Turn off and unplug product Test GFCI receptacle If functioning properly reset GFCI plug in product and turn on 4 Have product repaired Product begins to operate abnormally 1 Problem with appliance 2 Rated load capacity exceeded 1 Immediately unplug appliance Have appliance repaired by a qualified technician or replace appliance 2 Lower the number of items plugged...

Отзывы: