Page 9
For technical questions, please call 1-888-866-5797.
ITEM 59134
SAFETY
SETU
p
Op
ERA
TION
M
AINTENANCE
Initial Tool Set Up/Assembly
Read the ENTIRE IMpORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
TO pREVENT SERIOUS INJURY:
Operate only with proper spark arrestor installed.
Operation of this equipment may create sparks that
can start fires around dry vegetation.
A spark arrestor may be required. The operator
should contact local fire agencies for laws or
regulations relating to fire prevention requirements.
At high altitudes, the engine’s carburetor, governor,
and any other parts that control the fuel-air ratio will
need to be adjusted by a qualified mechanic to allow
efficient high-altitude use and to prevent damage to the
engine and any other devices used with this product.
Note:
For additional information regarding the
parts listed in the following pages, refer to the
Assembly Diagram near the end of this manual.
NOTICE:
This Generator is not intended to power
sensitive electronic equipment without the addition
of an appropriate line conditioner and surge
protector (both not included).
Sensitive electronic
equipment includes, but is not limited to,
audio/video equipment, some television sets,
computers, and printers.
Sensitive electronic
equipment should be operated on approved inverter-
type generators or pure sine wave generators.
Wheel Kit, #64788 (sold separately)
can be used with this Generator.
Battery Setup Instructions
All generators can be started using the recoil
method. This Generator requires installation
of a battery to operate the electric start feature.
Connect the battery to the Generator engine:
1. Place a fully charged, lead-acid 12 V battery (not
included) in the battery holder on the Generator.
2. Bolt in place using the hardware
included with the Generator.
3. Attach the positive (red) cable connector
from the engine to the Positive Terminal
on the battery. Connect cable securely to
prevent disconnection and short circuits.
4. Attach the negative (black) cable connector
to the negative battery terminal.
positive
Connector
Negative
Connector
Hardware
Battery
Note:
Use 12V, 9Ah minimum sealed Lead-Acid Battery
only.
Thunderbolt Battery #62586 (sold separately)
can be used with this generator.