Page 7
For technical questions, please call 1-888-866-5797.
ITEM 59134
SAFETY
SETU
p
Op
ERA
TION
M
AINTENANCE
Functional Description
Specifications
Generator
Output
120 / 240 VAC, 60 Hz
60.4A at 120V; 30.2A at 240V
7,250 Running Watts (9,000 Max. Starting Watts)
Battery needed for electric start
(not included)
12 V, lead acid, 9Ah Minimum
Electrical Receptacle
Two 3-Prong, duplex NEMA #5-20 120 V GFCI
One 3-Prong, NEMA #L5-30 twistlock 120 V
One 4-Prong, NEMA #L14-30 twistlock 120 V / 240 V
One DC Outlet 12 VDC
Engine
Displacement
420 cc
Engine Type
Horizontal Single Cylinder 4 stroke OHV
Cooling System
Forced air cooled
Fuel
Type
87+ octane stabilizer treated unleaded gasoline
Capacity
7.79 Gallon / 29.50 Liter
Engine Oil
Type SAE
10W – 30 above 32° F
5W – 30 at 32° F or below
Capacity
1 Quart
Spark Plug
Type
NHSP
®
/ Torch
®
F6TC
Gap
0.028″ – 0.031″
Valve Clearance
Intake
0.004″ – 0.006″
Exhaust
0.004″ – 0.006″
Run Time @ 50% load
Up to 13 hr.
Available accessories
Wheel kit (sold separately)
The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental
Protection Agency and by the California Air Resources Board (also known as CARB). For warranty information,
refer to the last pages of this manual.
Components and Controls
Fuel Cap
Frame
Starter Handle
DC Circuit Breaker
Fuel Valve
power Switch
AC Circuit Breakers
Choke
Low Oil Indicator
GFCI AC Receptacles (5-20R)
Air Filter
DC Receptacle
Ground Terminal
AC Receptacle (L5-30R)
CO Sensor
Fuel Gauge
AC Receptacle (L14-30R)
Battery Mounting Bracket