HAPP 40
© 2013 HAPP Australia Pty Ltd
Version 8
30
|
P a g e
This white connector is used to attach an limit switch to the hoist. In cases where this
connector is not required, bridge(connect) these two wires to disable the connector.
Important: The limit switch connector should be connected and either shielded with
extra insulation or moved back inside the control box. If the limit switch is operational
the 4Amp fusible link must be installed. Extra inline fuse holders are available from
HAPP if required.
Important:
The limit switch is wired to the top crossbar on HAPP 40.
Ensure the hoses are pulled to the top of the column and that the limit switch wires
are not held in the hydraulic line clamps. If they are remove them and attach to hose
with cable ties.
Electrical wiring – AS3000
Power wiring will be according to the following Australian standard (AS3000),
Electricians must remove the top cover and verify ground , neutral and phase
connections as well as limit switch connection if required and connect wires
according to the following specification.
Phases
Neutral
Earth
Australia, New Zealand (AS/NZS
3000:2007 3.8.3)
,
,
Connect to:
3/L2
5/L3
Motor
Chassis