-2-
Input code for input type and range
Setting Mode
5
6
7
8
9
®
3
4
DISP 1
DISP 2
DISP 3
1 2 3
Power On
1) Operation
mode
Process value
Set value
Process value
Output amount
PV
SV
PV
SV
Control group
Auto-tuning group
Setting value group
PID group
Alarm group
RET. group
COM. group
Output group
Input group
HBA group
for 3 seconds
for 3 seconds
for 3 seconds
for 3 seconds
for
3 seconds
HOTKEY
+
Level
+
Quick menu
+
Ramp
function
type A
Ramp
function
type B
※ In the standard type, Retransmission output (RET) is only available from OUT2.
(1) Standard type
Type
Output
code
OUT1(Heating)
OUT2
Default
Relay
SSR/SCR/RET
Relay
SSR/SCR/RET
Standard
Type
0
Control output
(ON/OFF)
-
AL2
(Alarm 2
output)
RET
(retransmission
output)
1
1
-
SSR
2
SCR(4 - 20 mA)
3
Control output
(PID)
-
Input signal
Input signal
Input type
Range (℃)
Accuracy
Note
Thermocouple
(TC)
1
K
*1
-200 ~ 1370
±0.5 % of FS ±1 Digit
•FS is the measurable range
from the maximum to the minimum
for each range.
• Digit is the minimum display value
❇1 below 0 ℃ :
±1.0 % of FS ± 1 digit
❇2 0 ~ 400℃ range :
±10 % of FS ± 1 digit
❇3 20 → KPt100 Ω (C1603)
21, 22 → Pt100 Ω(IEC751)
*4 In case of using Current input,
Resistor 250 Ω 0.1 % should be
installed in the input terminal.
2
K
*1
-199.9 ~ 999.9
3
J
*1
-100.0 ~ 999.9
4
E
*1
-100.0 ~ 999.9
5
T
*1
-199.9 ~ 400.0
6
R
0 ~ 1700
7
B
*2
0 ~ 1800
8
S
0 ~ 1700
9
L
*1
-100.0 ~ 900.0
10
N
-200 ~ 1300
±1.0 % of FS ±1 Digit
11
U
*1
-199.9 ~ 400.0
±0.5 % of FS ±1 Digit
12
W
0 ~ 2300
13
Platinel II
0 ~ 1390
Resistance
temperature
detector
(RTD)
20
KPt100 Ω
*3
-199.9 ~ 500.0
±0.5 % of FS ±1 Digit
21
Pt100 Ω *3
-199.9 ~ 640.0
22
Pt100 Ω
*3
-200 ~ 640
DC voltage
(VDC / ㎷ DC)
30
1.000 - 5.000 V DC
-1999 ~ 9999
Scaling function(SL-H/SL-L) necessary
±0.5 % of FS ±1 Digit
31
0.0 - 100.0 ㎷ DC
DC current
30
4 - 20 ㎃ DC *4
█ Control Output Composition
HX series is a multi-control-output temperature controller. It can have relay ON/OFF,
SSR voltage pulse output, 4 – 20 mA current output as a control output by selecting an option in the parameter.
If the option is chosen like below in the output parameter ( ) of the output group ( ) in standard temperature controller
0 : Relay ON/OFF control is as a control output.
1 : SSR output is as a control output.
2 : 4 – 20 mA DC current output is as a control output.
3 : Relay PID control is as a control output.
(2) Heating / Cooling Type ( simultaneous control)
Type
Output
code
OUT1(Heating)
OUT2
Default
Relay
SSR/SCR/RET
Relay(AL2)
SSR/SCR/RET
Heating /
Cooling
type
4
-
SSR
AL2
(Alarm 2
output )
SSR
4
5
-
SCR(4 - 20 mA)
6
Control
output (PID)
RET
(retransmission
output)
7
-
SSR
SCR
(4 - 20 mA)
8
-
SCR(4 - 20 mA)
9
Control
output (PID)
RET
(retransmission
output)
10
-
SSR
Control output
(PID)
RET
(Retransmission
output)
11
-
SCR(4 - 20 mA)
12
Control
output (PID)
-