2.3.1 General Safety 

 

• 

 Read and understand the manual and all safety signs before you connect power 
supplies to operate or adjust the FeedStation. 

 

• 

Only trained persons are permitted to operate the FeedStation. A first

-

aid kit must 

be available near the FeedStation. Store in a highly visible place.

 

• 

A carbon dioxide or foam fire extinguisher must be available near the FeedStation. 
Store the fire extinguisher in a highly visible place.

 

• 

Install all protective covers and guards before you operate the FeedStation.

 

• 

Wear the correct protective clothing and equipment. Disconnect and isolate the 
electrical power supply before you clean or do maintenance on the FeedStation, 
also be sure that the compressed air supply is depressurised. 

 

• 

Know the emergency medical centre number for your area.

 

• 

Contact your nearest milking equipment dealer provider if you have any questions

 

• 

Review safety related items with all operators frequently (annually). 

 

 

2.3.2 Electrical Safety

 

• 

Only an authorized electrician must install the electrical power supply for the 
FeedStation.

 

• 

Make sure the electrical grounding of the electrical system and all parts of the 
FeedStation meet the local rules and regulations.

 

• 

Replace any damaged electrical lines, conduits, switches and components immedi-
ately.

 

• 

Isolate the electrical power supply before you open the lid of the FeedStation to 
work on the electrical system. 

 

 

2.3.3 Installation Safety 

 

• 

 Read and understand the instructions in this manual.

 

• 

Make sure the FeedStation is correctly installed. 

 

 

2.3.4 Operating Safety 

 

• 

Read and understand the applicable manual and all safety signs before you con-
nect power supplies to operate or adjust the FeedStation.

 

• 

Only trained persons are permitted to operate the FeedStation.

 

• 

Switch off the electrical power supply by taking plug out of the power point and 
secure the plug before you clean or do maintenance on the FeedStation. 

 

• 

Install the covers and guards before you operate the FeedStation.

 

• 

Keep hands, feet, hair and clothing away from all the electrical parts.

 

• 

Keep unauthorized persons, especially small children away from the FeedStation at 
all times.

 

• 

Before the electrical supply is attached to the FeedStation, make sure all parts are 
tight and that all the parts are in good condition.

 

• 

Contact your nearest milking equipment dealer if you have any questions. 

 

 
 

Содержание FeedStation 42000

Страница 1: ...g instruction Article number 010 084 000 Date January 2017 Version 3 5 Translation of Original Instructions for use Doetinchem The Netherlands www hanskamp nl Voerstation Out of parlour feeder Futters...

Страница 2: ...l information All information in this manual has been compiled with care Hanskamp shall not be liable for errors or faults in this manual The recommendations are meant to serve as guidelines All instr...

Страница 3: ...eedStation means it is possible to link multiple FeedStations next to each other This is done at a remarkably low cost as each additional FeedStation only needs one sidebar Due to it s open character...

Страница 4: ...FeedStation YOU must make sure that you and anyone else who is going to operate maintain or work in the vicinity of the FeedStation knows all the related SAFETY information in this manual YOU are the...

Страница 5: ...l power supply for the FeedStation Make sure the electrical grounding of the electrical system and all parts of the FeedStation meet the local rules and regulations Replace any damaged electrical line...

Страница 6: ...al power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the FeedStation Wear protective clothing and safety goggles when you do work on the pneu...

Страница 7: ...f various parts Transport and storage The FeedStation will be shipped on a pallet This pallet is completely sealed and the corners are covered with tape to prevent damage The FeedStation is also store...

Страница 8: ...ind the right position for the sticker Remove a small portion of the foil on the back Place the sticker on the surface and press a small portion of the self adhesive layer onto the surface Carefully r...

Страница 9: ...ble the side fences Item No 004 200 000 Do this using the double T clamps Item No 004 115 000 with the standing tube Item No 004 204 000 in between Fig 4 3 Mount one of the two frames Item No 004 202...

Страница 10: ...he locknut completely otherwise it will not be possible to push up the carriage bolt and it will not serve its cleaning purpose 8 Attach the cable guide tube art nr 004 208 000 to the side rail Do thi...

Страница 11: ...the underside of the PipeFeeder should be at least 26cm height Be sure there is a good ventilation around the PipeFeeder Then turn tight the brackets on the PipeFeeders and the side fence Important C...

Страница 12: ...n the connecting gate can be used as cable conduits to feed the ca bling upwards Connecting FeedStations It is easy to connect FeedStations alongside each other All that is needed is one inter vening...

Страница 13: ...n the event of faults Hanskamp cannot be held responsible for consequential damage Nr Release datum Chapter s Remarks 1 08 2013 First release 1 1 09 2013 All Change to long version of PipeFeeder 1 2 1...

Страница 14: ...supply the following options for the FeedStation concentrates box 27000 PipeFeeder concentrate feed dosator 28000 PipeFeeder low capacity dosator 004 030 000 Universal L port closing gate 002 400 000...

Страница 15: ...nds www hanskamp nl en FeedStation EN 42000 Annex 2 Loose components It is possible to reorder loose components from your supplier for maintenance or for any other reason When doing so please use the...

Страница 16: ...x60 a2 DIN 603 4 001 703 000 Sticker warning risk of impact 1 001 707 000 Washer M10 DIN 125 8 8 ev 24 001 741 000 Bolt M8x55 a2 DIN 933 8 001 746 000 Bolt M10x30 DIN 933 8 8 ev 4 001 769 000 Prevaili...

Страница 17: ...anskamp AgroTech B V the Netherlands www hanskamp nl en FeedStation EN 42000 Hanskamp AgroTech B V Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel 31 0 314 393 797 Fax 31 0 314 393 826 www hansk...

Отзывы: