56 / Hanshin
6. Troubleshooting
Trouble
The safety valve suddenly
operates during operation
Does the safety valve operate
within the rated pressure?
Is the operation pressure set
below the rated pressure?
Re-set the pressure
according to the rated
pressure.
Is the front/end diff.
pressure of the separator
within 1.0 bar?
Is the pressure suddenly
changed and indicated?
Is the Micom’s pressure
indicating 0.0 bar during
operation?
The pressure sensor is
detached from Micom.
Or, the sensor cable or
sensor is in trouble.
The compressor needs
inspecting in detail. Pleae
contact your dealer or our
A/S service center.
Safety valve fault
Checklist
Potential trouble causes
Y
N
Oil separator is blocked
Pressure sensor fault
Y
Y
N
Y
Y
N
N
N