45
[Abnormal Temp. sensor, Trip display]
When the discharge temperature detection sensor is in trouble
“pxx” troubleshooting page is displayed
Refer to page 53 and control circuit
Checkpoint : temperature sensor, temperature sensor wiring
[Abnormal pressure sensor, Trip display]
When the discharge pressure control sensor is in trouble
“pxx” troubleshooting page is displayed
Refer to page 53 and control circuit
Checkpoint : pressure sensor, pressure sensor wiring
[Air filter displacement display]
When the air filter use time reaches to the replacement
limit(setting)
Initial setting : 3000 hrs
Checkpoint : filter replacement and use time reset
If pressing [STOP] button for 10 seconds, [RESET ! OK] message is
displayed and the use time is reset.
[Oil Filter replacement display]
When the oil filter use time reaches to the replacement
limit(setting)
Initial setting: 3000 hrs
Checkpoint : filter replacement and use time reset
If pressing [SCHEDULE] button for 10 seconds, [RESET ! OK] message is
displayed and the use time is reset.
[Oil Separator replacement display]
When the oil separator use time reaches to the replacement
limit(setting)
Initial setting : 3000 hrs
Checkpoint : filter replacement and use time reset
If pressing [STOP] and SCHEDULE]buttons for 10 seconds, [RESET ! OK]
message is displayed and the use time is reset.
[Internal pressure rise auto start stand-by display]
If the internal pressure[P1] is 2.0 bar and higher after
pressing [START] button, the auto start stand-by display
appears.
If the internal pressure falls under 2.0 bar, it automatically
starts.
GRH3 star-delta
User’s Manual
Содержание GRH 3 series
Страница 1: ...User s Manual of Compressor...
Страница 60: ...60 Hanshin 8 Control System 8 1 Compressor Configuration Layout 8 Control System...
Страница 62: ...62 Hanshin 8 Control System 2 Micom Controller GRH3 50A 100A...
Страница 63: ...63 GRH3 25A 30A 35A 50A Star delta GRH3 star delta User s Manual...
Страница 64: ...64 Hanshin 8 Control System GRH3 75A 100A Star delta...
Страница 74: ...74 Hanshin 12 Quality Warranty 13 Outside Drawing by Models 1 GRH3 20A 25A 30A 35A 13 Outside Drawing by Models...
Страница 75: ...75 2 GRH3 50A GRH3 star delta User s Manual...
Страница 76: ...76 Hanshin 13 Outside Drawing by Models 3 GRH3 75A 100A...
Страница 77: ...4 GRH3 75W 100W GRH3 star delta User s Manual 77 Appearance...
Страница 79: ......