46 / Hanshin
5. Operations
[Line pressure rise auto start stand-by display]
Auto start stand-by display when the compressor’s internal
pressure [P2] is higher than the setting after [START ]button
It automatically starts when P2 pressure falls under 6.0 bar.
[No load operation display]
No-load operation when the pressure rises higher than the
no-load start pressure due to reduced air volume. It operates
under no-load for the set time(10 minutes) and automatically
stops.
[Auto stop display]
When the compressor automatically stops under no load
operation
It automatically starts if the pressure falls under the preset
pressure (6.0 Bar).
[Schedule Operation selection display]
When pressing schedule operation button
If selecting the schedule operation mode and pressing
START button, it operates and stops according to the
predefined time.
[Stop delay operation display]
If pressing STOP button, the compressor stops after 10
second no-load operation
Stop delay time count
[Discharge high temp. check alarm display]
High temperature check alarm is displayed if the discharge
temperature is between 95
~110
Notes: if discharge temperature is higher than 110 , a trip attributable to
excessive temperature occurs and the compressor stops.
Содержание GRH 3 series
Страница 1: ...User s Manual of Compressor...
Страница 60: ...60 Hanshin 8 Control System 8 1 Compressor Configuration Layout 8 Control System...
Страница 62: ...62 Hanshin 8 Control System 2 Micom Controller GRH3 50A 100A...
Страница 63: ...63 GRH3 25A 30A 35A 50A Star delta GRH3 star delta User s Manual...
Страница 64: ...64 Hanshin 8 Control System GRH3 75A 100A Star delta...
Страница 74: ...74 Hanshin 12 Quality Warranty 13 Outside Drawing by Models 1 GRH3 20A 25A 30A 35A 13 Outside Drawing by Models...
Страница 75: ...75 2 GRH3 50A GRH3 star delta User s Manual...
Страница 76: ...76 Hanshin 13 Outside Drawing by Models 3 GRH3 75A 100A...
Страница 77: ...4 GRH3 75W 100W GRH3 star delta User s Manual 77 Appearance...
Страница 79: ......