Hansa C65RX O&M Manual
–
OM-029 First Release 4/05/2021
© Hansa Chippers 2021
31
Maintenance & service intervals
Maintenance interval - service hours
10 or
50 or
100
250
500
800
1000
3000
Yearly
As req.
Service
Daily
Weekly
Drive belts tension
–
initial
check
Initial
Track tension
–
initial check
Initial
Engine oil level
–
check
•
Cooling air duct screen
–
check/clean
•
Air cleaner element
–
clean
•
•
General grease points
(see
section in manual “
” or weekly service checks
label on housing wall)
•
Knives
–
check, sharpen or
replace
•
•
Drive belts tension -
check/adjust
•
Hydraulic pump belt tension -
check/adjust
•
Track gearbox oil
–
initial
change
Initial
Hydraulic system
–
check
•
Engine fan belt
–
check
•
Engine oil & filter
–
change
•
•
Hydraulic oil filter - replace
•
Battery electrolyte level &
terminals - check
•
Engine fuel filter
–
replace
•
Outlet chute
–
remove & clean
swivel
•
Feed roller tension springs -
replace
•
•
Anvil
–
check knife clearance
and bolt torque
•
•
Hydraulic filter
–
replace
•
Grease engine output shaft
–
Hayes coupling
•
Air cleaner element
–
replace
•
Feed roller teeth
–
sharpen
•
•
Track gearbox oil - replace
•
Hydraulic oil
–
replace
•
Engine fan belt - replace
•
Engine
–
Valve clearances (refer
to Deutz service manual)
•
Engine
–
3000-hour service by
authorised Deutz specialist
(refer to Deutz service manual)
•
Nuts & bolts
–
check torque &
replace if worn
•
Battery
–
replace
•
Drive belts
–
replace
•
Hydraulic pump belt
–
replace
•
Knives
–
replace
•
Anvil
–
replace
•
Hazard labels
–
replace
•
Rubber tracks - replace
•