2

Dear Customer,
Thank you for choosing a Hanna Instruments product.
Please read this instruction manual carefully before using the meter. 
This manual will provide you with the necessary information for  correct 
use of the instrument, as well as a precise idea of its versatility. If you 
need additional technical information, do not hesitate to e-mail us at 
[email protected].

WARRANTY ..................................................................................2
PRELIMINARY EXAMINATION .........................................................3
GENERAL DESCRIPTION .................................................................3
FUNCTIONAL DESCRIPTION ............................................................4
SPECIFICATIONS ...........................................................................5
OPERATIONAL GUIDE ....................................................................6
pH CALIBRATION ..........................................................................8
pH VALUES AT VARIOUS TEMPERATURES .....................................10
EC/TDS CALIBRATION ..................................................................11
EC/TDS CONVERSION FACTOR ......................................................11
BATTERY REPLACEMENT ..............................................................12
PROBE MAINTENANCE ................................................................13
ACCESSORIES .............................................................................14

HI9811-5

 is guaranteed for two years against defects in workmanship 

and materials when used for their intended purpose and maintained 
according to instructions. Electrodes and probes are guaranteed for six 
months. This warranty is limited to repair or replacement free of charge.
Damage due to accidents, misuse, tampering or lack of prescribed 
maintenance is not covered.
If service is required, contact your local Hanna Instruments Office. 
If under warranty, report the model number, date of purchase, serial 
number and the nature of the problem. If the repair is not covered by the 
warranty, you will be notified of the charges incurred. If the instrument 
is to be returned to Hanna Instruments, first obtain a Returned Goods 
Authorization number from the Technical Service department and then 
send it with shipping costs prepaid. When shipping any instrument, 
make sure it is properly packed for complete protection.

WARRANTY

TABLE OF CONTENTS

Содержание HI 9811-5

Страница 1: ...1 www hannainst com Instruction Manual HI9811 5 Portable pH EC TDS C Meters...

Страница 2: ...against defects in workmanship and materials when used for their intended purpose and maintained according to instructions Electrodes and probes are guaranteed for six months This warranty is limited...

Страница 3: ...cking material until you are sure that the instrument functions correctly Any defective item must be returned in the original packing together with the supplied accessories HI9811 5 is the complete ve...

Страница 4: ...obe 2 Liquid Crystal Display 3 pH range selection key 4 S cm EC range selection key 5 mg L TDS selection key 6 pH offset calibration knob 7 EC TDS calibration knob 8 C Temperature selection key 9 On O...

Страница 5: ...0 5 C Conversion Factor 0 5 pH Calibration Manual 1 point through offset trimmer EC TDS Calibration Manual 1 point through slope trimmer EC TDS Temperature Compensation Automatic from 0 to 70 C 32 to...

Страница 6: ...ak the tip in HI70300 storage solution for 30 minutes to reactivate it To take a pH measurement simply submerge the tip 4 cm 1 of the probe into the sample to be tested Select the pH mode Stir briefly...

Страница 7: ...is in TDS mode TAKING TEMPERATURE MEASUREMENTS Submerge the tip 4 cm 1 of the probe into the sample to be tested Select the C mode Stir briefly and wait a couple of minutes for the reading to adjust...

Страница 8: ...measure acidic samples or pH10 01 HI7010 for alkaline measurements If you need to calibrate to NIST standards use pH6 86 HI7006 instead of pH7 01 and pH9 18 HI7009 instead of pH10 01 PROCEDURE Connec...

Страница 9: ...cm 1 into the solution The thermometer has to be close to the probe If turning the knob the needed value can not be reached clean the probe see the Probe Maintenance section If also after the probe cl...

Страница 10: ...8 7 03 9 22 10 06 25 77 4 01 6 86 7 01 9 18 10 01 30 86 4 02 6 85 7 00 9 14 9 96 35 95 4 03 6 84 6 99 9 11 9 92 40 104 4 04 6 84 6 98 9 07 9 88 45 113 4 05 6 83 6 98 9 04 9 85 50 122 4 06 6 83 6 98 9...

Страница 11: ...quested to calibrate the meter only in EC or TDS range The other range is thus automatically calibrated PROCEDURE Pour approximately 4 cm 1 of a conductivity calibration solution e g HI70031 into a be...

Страница 12: ...battery immediately When the battery level is so low that it may cause unreliable measure ments the meter turns off Battery replacement must only take place in a nonhazardous area using a 9V alkaline...

Страница 13: ...a good performance of the probe a frequent cleaning is recommended For this purpose soak it in Hanna Instruments HI700661 Cleaning Solution for 5 minutes Notes For particular dirt as for example prot...

Страница 14: ...ottle HI7009L pH9 18 buffer solution 500 mL bottle HI7010L pH10 01 buffer solution 500 mL bottle CONDUCTIVITY TDS CALIBRATION SOLUTIONS HI7031L 1413 S cm solution 500 mL bottle HI7032L 1382 ppm mg L s...

Страница 15: ...advance notice Before using this product make sure it is entirely suitable for your specific application and for the environment in which it is used Any variation introduced by the user to the suppli...

Страница 16: ...ark 584 Park East Drive Woonsocket RI 02895 USA www hannainst com Local Office Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA Phone 800 426 6287 Fax 401 765...

Отзывы: