background image

 

 

 

 

 

 

 

 

 

 

 

 

WARNINGS

 

Read Before Operating

 

Th

e Neo’s User’s Guide must be carefully read by 

all individuals who have or will have the 

responsibility of using, maintaining or servicing this 

product. The product will perform as designed only 

if it is used, maintained and serviced in accordance 
with the manufacturer’s instructions. 

 

 

Caution

 

 

Change battery only in area known to be 

non-hazardous. 

 

Use 

only 

mPower

’s  battery  PN: 

12.02.02.0017 and 12.02.02.0019 . 

  Attention:

 

 

Changez  la  batterie  uniquement  dans 

une  zone  connue  pour  être  non 

dangereuse. 

 

Utiliser  uniquement  la  batterie  mPower 

PN: 12.02.02.0017, 12.02.02.0019. 

  Warning

 

 

Never operate the monitor when the cover is removed.   

 

Remove the monitor cover only in area known to be non-hazardous. 

 

Substitution of components will impair suitability for intrinsic safety and void 
warranty.   

 

Always bump test with a known concentration gas to confirm the instrument is 
functioning properly before use. 

 

Before use, ensure that the ESD film on the display is not damaged or peeling. 

Avertissement

 

 

N'utilisez jamais le moniteur lorsque le couvercle est enlevé. 

 

Retirer le couvercle du moniteur et la batterie uniquement dans une zone connue 
comme non dangereuse. 

 

La substitution de composants compromettra l'aptitude à la sécurité intrinsèque 
et annulera la garantie. 

 

Il est recommandé de tester avec un gaz de concentration connu pour confirmer q
ue l'instrument fonctionne correctement avant de l'utiliser.   

 

Avant de l’utiliser, assurez

-vous que le film ESD sur l'écran n'est pas endommagé 

ou épluché.                      

Precautions 

 

For  maximum  safety,  the  accuracy  of  the  instrument  should  be  checked  by 
exposing it to a known concentration calibration 

gas before each day’s use.

 

 

Ensure that the gas inlet is not blocked. 

 

When replacing batteries, dispose of old ones properly. 

 

For optimal accuracy, allow the unit to warm up for 2 minutes after the start-up 
cycle is complete.   

 

Make sure the water-trap filter is clean & replaced timely. 

 

Remove the sensor only if absolutely necessary. Zero & span calibration are 
required if the sensor is moved. 

 

User Interface 

Four key operation, one big LCD with LED 

backlight, four red alarm LEDs, and one buzzer.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

NEO 

MP18X Series 

Quick Start Guide 

V1.0

 

 

LED Alarm 

LCD 

Left Key 

(Esc/Move 

Cursor Left) 

Right Key 

(Enter/Move 

Cursor Right) 

UP Key 

(Confirm/ 

Number Increase) 

Down Key 

(Power/Number 

Decrease) 

Charge/Comm Port 

Buzzer 

Sensor 

Gas Inlet 

Water-trap Filter 

 

mPower Electronics Inc. 

3046 Scott Blvd. Santa Clara, CA 95054 

www.mpowerinc.com 

[email protected] 

 

 
 

 
 

Reviews: