33
Appendix 2
Code:
Meaning:
5
5
Bot stop – Right hand.
Top stop – Left hand.
Description:
End limits activated.
Telephone fault finding action:
Ask client to tap trunnion guards in case they are stuck.
If this does not correct the fault – send engineer.
On site fault finding action:
Check end limit circuit and trunnion guards.
Code:
Meaning:
6
6
Bot pressure – Right hand.
Top pressure – Left hand.
Description:
Safety edge (down/up direction) activated
– footplate, underpan.
Telephone fault finding action:
Ask client to tap footplate edges. If this does not
correct the fault – send engineer.
On site fault finding action:
Check footplate bottom and downside and chassis
underpan.
Code:
Meaning:
7
7
Low voltage.
Description:
Batteries approaching critical level.
Telephone fault finding action:
Ask client to drive lift to charge contacts – if ‘Okay’
code does not show send engineer. If the lift will not
drive – send engineer.
On site fault finding action:
Drive lift to charge contacts. Check charging circuit if
‘Okay’ code not displayed. If lift will not drive replace
batteries and check charging circuit.
Code:
Meaning:
8
8
Up direction – Right hand
Down direction – Left hand.
Description:
Shows when toggle switch is activated in up/down
direction.
Telephone fault finding action:
None.
On site fault finding action:
None.
Code:
Meaning:
9
Up direction – Left hand.
Down direction – Right hand.
Description:
Shows when toggle switch is activated in down/up
direction.
Telephone fault finding action:
None.
On site fault finding action:
None.
Code:
Meaning:
b
Switch active.
Description:
A switch is active at power on i.e. Toggle Up,
Toggle down, IR Up IR down or learn.
Telephone fault finding action:
Send engineer.
On site fault finding action:
A short circuit has occurred on toggle circuit
– check circuit.
Code:
Meaning:
A
A
Hinge open.
Description:
Telephone fault finding action:
None.
On site fault finding action:
None.
Code:
Meaning:
C
C
IR Address fail.
Description:
The IR Address (Dip switch) does not match.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Re-program handsets.
Содержание MINIVATOR 2000
Страница 1: ...INSTALLATION MANUAL MINIVATOR 2000 XXXXXXXX...
Страница 11: ...Electrical connections MINIVATOR 2000 INSTALLATION MANUAL 11 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24...
Страница 13: ...MINIVATOR 2000 INSTALLATION MANUAL 13 Power pack Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32...
Страница 48: ...48 MINIVATOR 2000 INSTALLATION MANUAL Appendix 5 Inside track details...
Страница 49: ...MINIVATOR 2000 INSTALLATION MANUAL 49 Notes...
Страница 50: ...50 MINIVATOR 2000 INSTALLATION MANUAL Notes...
Страница 51: ...MINIVATOR 2000 INSTALLATION MANUAL 51 Notes...