79
The powered swivel operates when the directional safety line is interrupted.
The powered swivel does not operate when the general safety line is interrupted.
The powered swivel does not function; the lift can ride
•
The lift is making its first ride since calibration
The LED lights up and becomes dim upon joystick operation to activate the automatic swivel feature.
•
The powered swivel function is not programmed on the data card.
•
Wire break between K3-5 /K6-9 and the swivel motor
•
Wire break between K3-6
The powered swivel does not function; the lift cannot ride
The LED flashes upon joystick operation in one direction and remains dim in the other direction (the lift
beeps upon operation of the joystick). The lift is on the charge station
•
See chapter 4
16
|
The powered swivel seat
Technical manual