59
32
|
Rescuing the user
Move the user to safety by turning the chair in the direction of the stairs. Lock the chair in place. Unfasten
the safety belt. The client may now step in the direction of the stairs and proceed to the floor above.
Remove the fault; if necessary, you may ride the chair lift to the floor level using the calibration switches,
for which please refer to the manual.
Instructions for rescuing a user seated on a chair lift of the type
Van Gogh or Rembrandt that is still at the top of the stairs.
Check the status of the chair lift via the lamp in the on/off switch.
Remove faults in the chair lift that could pose a danger to the user.
For example, faults in the footrest safeguard, in the operation,
detection strips or the chair position switch.
Never ride with the user on the lift when a safety measure is swit-
ched off.
If it is not possible to remove the fault without danger to the user,
first release the user:
In such case ensure that you are positioned above the user and the
chair lift at all times.