background image

71

The LED flashes upon joystick operation in one direction and remains dim in the other 

direction (the lift beeps upon operation of the joystick). The lift is on the charge station.

Connect the short-circuit connectors K6 and K9

A. The lift moves after operation of the direction switch (DS)

The fault is located in the chair

 

• 

The seat position switch is switched off/faulty

 

• 

Wire break between K6-6 and E1-6 (K6-6 and C1-6)

 

• 

Wire break between K6-7 and E1-7 (K6-7 and C1-7)

 

• 

Wire break between E11-3 and E11-4 (C14-3 and C14-4)

 

• 

Wire break between E9-2 and E9-3 (C12-2 and C12-3)

 

• 

Wire break between E20-2 and K4-5 (C8-2 and K4-5) (pow sw. only)

 

• 

One of the footrest edges is activated

 

• 

One of the footrest switches is faulty

 

• 

The seat frame bottom detection is activated

 

• 

The seat frame bottom switch is faulty

 

• 

Wire break between K9-1 and K9-2

 

• 

Wire break between K9-3 and K9-4

 

• 

Earth short at K6-6, K6-7, K9-1, K9-2, K9-3, K9-4

B. The lift does not move after operation of the direction switch (DS)

The fault is located in the unit

The lift does not operate in the traction mode

 

• 

A final limit switch is off/activated

 

• 

Wire break between K5-5 and K5-6

 

• 

Wire break between K4-8, K7-3, K7-1, K8-1, K8-3 and K6-6

 

• 

Wire break between K4-9 and K6-7

 

• 

One of the cover safety edges is activated

 

• 

The cover detection switch is faulty

 

• 

Wire break between K4-4 and K9-3

 

• 

Wire break between K4-5 and K9-4

 

• 

Wire break between K4-6 and K9-1

 

• 

Wire break between K4-7 and K9-2

The lift does not operate in the traction mode

 

• 

The tilt switch is activated/faulty/not connected

 

• 

Wire break between K3-1/2/3/4 and the tiltswitch C5

 

• 

Earth short K3-1, K3-2, K3-4, K4-4, K4-5, K4-6, K4-7, K4-8, K4-9, K5-4, K2-4

4  

|

  The lift does not move in both directions

Technical manual

Содержание FREECURVE Basic

Страница 1: ...Handicare Freecurve Technical manual...

Страница 2: ......

Страница 3: ...ding hinge Maintenance Lubrication Spare parts Multi meter Electronic parts Torque settings Circlip Threadlocking Handover approval Telephone instruction Rescuing the user Compatibility Rework procedu...

Страница 4: ...5 kg load at an angle of inclination 61 The Classic chair can be delivered in 3 colours beige anthracite and red The material has leathergrain finish The armrest footrest and seat fold up seperately T...

Страница 5: ...footrest The width of the armrests is adjustable 25 mm The height of the backrest 20 mm can be increased The Alliance chair can be delivered in 3 colours Brown wood cream leather White wash wood bord...

Страница 6: ...dth of stairs 690 mm Maximum of 2 landings Overhead clearance less critical Installation almost always feasible View on the stairs during the ride The rail of the Rembrandt chair lift is mounted on th...

Страница 7: ...ng folding hinge point Max number of remotes 10 Available with the Classic Elegance Alliance seat Optional for all models The lift can transmit an acoustic signal when the remote controls are used The...

Страница 8: ...rque settings have been applied Check the safety distances to obstacles are respected Check that the upper support has made minimal 4 rotations in the lower support Sign off the instructed person decl...

Страница 9: ...Installation Version 1 0 9 9 Technical manual...

Страница 10: ...Below you will find the QR codes for the installation videos Installation Track assembly Powerpack assembly Seat and footrest Configuring the footrest Hinged track Rail joints Powerpack calibration F...

Страница 11: ...ist of special tools Special tools Fitting kit rail joint C2043800 Grinder 11C00112 Allien key 7 11C00074 Rail angle tool AA12120 Torque wrench Electical override C5001000 Install support AA10622 Coup...

Страница 12: ...applying the prescribed torques C5001000 Electrical override Tool for riding the lift without pcb 11C00020 Spirit leveler Tool for applying the prescribed railangle 11C00074 Allien key 7 Tool for fix...

Страница 13: ...correspond to the wiring in the chair lift Each connector has its own number which corresponds with the numbers in the chapter fault finding 4 Electric schemes Technical manual Electric scheme Classi...

Страница 14: ...14 Handicare Freecurve...

Страница 15: ...15 Technical manual 11P00177 _ 141021 C25 C22 C23 C24 R R POWERED SWIVEL C26 GRAPHICS NO GRAPHICS...

Страница 16: ...s setting Both the drive motors are equipped with an electro mechanical brake The application and the release of the brake can be checked visually since the brake disks are visible from the outside On...

Страница 17: ...of a defective encoder the printed circuit does not know the position of the lift and will stop the lift Schematics Technical manual Video principle DC motor Traction motors Instruction replacement of...

Страница 18: ...e lift does not remain in the charge modus Two chargers are delivered on rails longer than 15 meters The batteries shall be disposed of by the dealer as small chemical waste Safety The power delivered...

Страница 19: ...ations and existing installations and can be installed by a certified engineer The LiFePo batteries can only be used in combination with the printed circuit version Q and T The LiFePo batteries requir...

Страница 20: ...tester enables you to check the voltage and to test the capacity of new batteries straight from the box as well as used batteries which may show abnormal Ah capacity A table on the side of the meter...

Страница 21: ...tor lamp should always be red when the chair lift stops at the charging station after a trip In due course the lamp turns green indicating that the batteries are charged The battery charger is suited...

Страница 22: ...talled on the Freecurve lift By activating this holiday switch the customer can switch of the battery power from the lift Customers should be aware that the lift does not run when this switch is in th...

Страница 23: ...owing switches have been included in the general safety edge Seat position switch Tilt switch Emergency switch Key operated switch Final limit switch The direction sensitive safety edge prevents the l...

Страница 24: ...Handicare Freecurve Schematics directional safety Schematics general safety Directional safety edges Left handed safety right Right handed safety right Left handed safety left Right handed safety lef...

Страница 25: ...tteries 5 Turn away the chair so the cardreader is reachable 6 Get the datacard out of the cardreader of the pcb it will give one beep 7 Put the empty datacard in the cardreader of the pcb 8 Wait for...

Страница 26: ...chair position motor The application and the release of the brake can not be checked visually since the brake disk is not visible from the outside The encoder in cooperation with the software of the...

Страница 27: ...in the general safety lines and it interrupts the safety line if the chair tilts 5 degrees with respect to the horizon Symptoms in case of a breakdown with the tiltswitch The lift runs in the traction...

Страница 28: ...ical 13 Armrest Joystick Left Right Installation Change armrest cable Elegance 11P00213 11P00223 11P00219 11P00233 11P00220 11P00335 11P00222 Classic changing left right Change parts Classic Elegance...

Страница 29: ...ometimes the owners of a public building request to switch off the joystick only by the keyswitch In that case the engineer has to change the wiring of the keyswitch in a way that the keyswitch is par...

Страница 30: ...ck not the remote control is operated in the direction of travel Tap The number of operations taps indicates the desired floor Tapping is pressing the joystick in the desired direction and releasing i...

Страница 31: ...s The positions can be changed on site by the engineer One way powered swivel Automatic swivel at the top The end user rides facing the opposite wall The chair can swivel on intermediate landings towa...

Страница 32: ...rail run out of 500 mm is always required A resistance of 340 is installed parallel to the powered swivel actuator The software on the printed circuit shall recognize this resistance before the lift c...

Страница 33: ...views The active seat The ActiveSeat supports and follows the movements of the user when sitting down or standing up from the stairlift seat The spring system in the ActiveSeat can be adjusted to suit...

Страница 34: ...34 Handicare Freecurve Schematics Service instructions Active seat Active seat 11P00346 11P00385 11P00421 Fold up Demonstrator...

Страница 35: ...legance and Alliance seat The powered footrest option enables the end user to fold unfold the footrest automatically The folding of the footrest can be done on any position of the rail The operation o...

Страница 36: ...stops automatically in the event that an object becomes jammed between the footrest and the stairs The chair lift can move again only once the control on the chair or the remote control has been used...

Страница 37: ...Footrest linkage Classic chair 11P00210 11P00211 11P00214 11P00216 11P00218 11P00349 11P00350 Replace footrest Changing footrest cable Powered footrest parts Footrest linkage Elegance chair Changing...

Страница 38: ...chargestation Video of the linking of the remotes Remotes Operation when using remote control when using remote control when using remote control when using remote control when using remote control wh...

Страница 39: ...915 Mhz remotes a conversion kit is available for 2 4 Ghz 915 Mhz remotes In the USA Stairlifts are delivered standard with 915 Mhz remotes 2 4 Ghz as back up 915Mhz 2 4 Ghz service instruction Insta...

Страница 40: ...the charge station in 2 pieces Contacts can also be installed after installation Charging contacts that are not necessary any more can be removed When a stairlift does not stop correctly on the charg...

Страница 41: ...the batteries The position of the contact is stated on the data card Malfunctions of the mechanism cannot be rectified and consequently in such instances the entire me chanism will need to be replace...

Страница 42: ...Handicare Freecurve 42...

Страница 43: ...functioning The stairlift must be serviced at least once a year If the stair lift runs over more than 2 floor and or has more than 2 users it needs at least 2 maintenance visits a year The service mus...

Страница 44: ...Handicare Freecurve 44 Stairlift maintenance Rail Unit mechanical Unit electrical Chair Finish Maintenance video s...

Страница 45: ...s of the grease is 5 years under normal conditions When grease is applied during servicing it is preferable to remove the old grease first so that any dirt present is also removed Molykote G4500 artic...

Страница 46: ...ndicare Freecurve 46 24 Spareparts Spareparts can be ordered from the webshop on www handicarepartners com For parts that are not on the webshop you can contact dealerservice for price and availabilit...

Страница 47: ...47 Technical manual Classic Alliance Elegance Unit Hinge Sparepart book complete Spareparts...

Страница 48: ...ect connector from the printed circuit board Push the measuring pins into the back of the connector Check that you are testing between the correct connector pins numbers No beep or a high resistance i...

Страница 49: ...a resistor can be calculated with below table Encoder A rotary encoder also called a shaft encoder is an electro mechanical device that converts the angular position or motion of a shaft or axle to a...

Страница 50: ...D stands for Light Emitting Diode It s a type of diode that emits light when it has a current flowing through itself The LED has two pins called anode and cathode The anode is the longest pin This is...

Страница 51: ...fracture of a bolt If the bolts in a dynamic situation are not tightened enough this will lead to a fatigue fracture Technical manual Dimensione nominale M4 M5 M6 M7 M8 M10 M12 Classe 8 8 10 9 12 9 8...

Страница 52: ...able to carry as much load and will fail more easily The circlips must be compressed by the minimum amount possible during assembly Circlips can never be reused As the clip slips into the groove list...

Страница 53: ...rength viscosity adhesion flexibility and temperature resistance These five parameters give anaerobic users considerable latitude in adjusting properties for optimum performance in specific applicatio...

Страница 54: ...engagement area or when using the stick product completely fill the root of the threads at the area of engagement 6 Assemble and tighten nut as usual Blind holes cap screws etc Liquid only 1 Clean all...

Страница 55: ...eral drops of LOCTITE Threadlocker 262 263 or 271 onto stud threads 5 Install studs 6 Position cover head etc 7 Apply drops of LOCTITE Threadlocker 242 243 onto exposed threads 8 Tighten nuts as requi...

Страница 56: ...on existing equipment RETIGHTEN nuts and apply LOCTITE Threadlocker 290 at the nut and bolt juncture LOCTITE THREADLOCKER QUICK SELECTOR Use Strength Loctite Product Color Small screws Low 222 Purple...

Страница 57: ...t which affects the safety the construction and or the functionality of the chairlift A certified engineer shall install the chairlift with original parts according to the delivered installation manua...

Страница 58: ...Handicare Freecurve 58 For the service desk there is a script available how to deal with service calls 31 Telephone instruction Telephone instruction Telephone instruction...

Страница 59: ...ated on a chair lift of the type Van Gogh or Rembrandt that is still at the top of the stairs Check the status of the chair lift via the lamp in the on off switch Remove faults in the chair lift that...

Страница 60: ...icare Freecurve 60 If you cannot remove the fault and the chair lift is to be removed from the rail you may do this using the test box Article number C5001000 in accordance with the instructions provi...

Страница 61: ...te data card The table below may also be useful if a unit is to be reused Freecurve 2 unit cannot be used on a rail with an inside curve C0020057 C0020081 and C0020090 are the only units that can be u...

Страница 62: ...rework by contacting dealer support Always mention this number on the outside of the returned rail parts Return only the rail parts without supports charge points folding hinge motors joints etc New...

Страница 63: ...which can be indicated on the installation drawing On each railpart the angles of the rail At each inclination the number of degrees that chair tilts forwards or backwards The total height The horizo...

Страница 64: ...eats and unit use the special boxes Claim for transport damage In case of a call for transport damage we need the following information before we can replace the damaged items Pictures of the damaged...

Страница 65: ...eople shall be reported to Handicare as soon as possible To have all information available the incident form shall be filled in as complete as possible The form is available under the chapter technica...

Страница 66: ...e DS Solution 10A After connecting the shorts the lift does not move on the DS Solution 2B After connecting the shorts the lift does not move on the DS Solution 5 After connecting the shorts the lift...

Страница 67: ...tick operation in one direction in the other direction the Led lights up and gets dimmed the lift gives one beep LED illuminates bright the lift does not move upon operating the joystick The LED flash...

Страница 68: ...3 Wire break between C8 2 and K4 5 powered swivel only Earth short at K6 6 K6 7 K9 1 K9 2 K9 3 K9 4 B The lift does not move after operation of the direction switch DS The fault is located in the unit...

Страница 69: ...rcuit is in operation Earth short at K1 1 K1 2 K2 5 K2 6 K4 12 K2 1 K2 2 The chair is inclined Option 1 If the lift stops and freezes in the middle of the rail Probable cause Grease on brakes levellin...

Страница 70: ...13 1 and C13 2 Wire break between E9 1 and E9 4 C12 1 and C12 4 Earth short at K6 1 B The lift does not move after operation of the direction switch DS The fault is located in the unit No voltage betw...

Страница 71: ...The seat frame bottom switch is faulty Wire break between K9 1 and K9 2 Wire break between K9 3 and K9 4 Earth short at K6 6 K6 7 K9 1 K9 2 K9 3 K9 4 B The lift does not move after operation of the d...

Страница 72: ...k operation in one direction in the other direction the Led lights up and gets dimmed the lift gives one beep Connect the short circuit connectors K6 and K9 A The lift moves after operation of the dir...

Страница 73: ...hort at K6 2 B The lift does not move after operation of the direction switch DS The fault is located in the unit Earth short at K4 13 When the lift beeps intermediate in user mode it is in the obliga...

Страница 74: ...n joystick operation in one direction Connect the short circuit connectors K6 and K9 A The lift moves after operation of the direction switch DS The fault is located in the chair One of the footrest e...

Страница 75: ...V No network voltage or plug is not in the socket The battery charger is defective Wire break in the cables from the charge stations Jack plug in the rail has loosened Check the voltage on the chargin...

Страница 76: ...problem is in the unit Wire break between K3 7 K7 2 and the carbon brush Wire break between K3 8 K8 2 and the carbon brush Earth short at K3 7 K3 8 The lift does charge when on a charge contact The pr...

Страница 77: ...seat leveling motor is faulty Wire break between K5 5 and K5 6 standard between 40 70 Wire beak between K5 7 and K5 8 standard between 0 2 Earth short at K5 1 K5 2 Low weak batteries Poor rail instal...

Страница 78: ...nge of the remote is insufficient Install a repeater The remote control is not linked to the lift The lift passes the extra charge point without stopping This is correct if a lift is called If this ha...

Страница 79: ...im upon joystick operation to activate the automatic swivel feature The powered swivel function is not programmed on the data card Wire break between K3 5 K6 9 and the swivel motor Wire break between...

Страница 80: ...l safety line final limit switch e stop keyswitch is interrupted The powered swivel seat does not stop in the centre postion and swivels towards the stairs The sensor C24 E24 is defective The powered...

Страница 81: ...e voltage on E15 3 Elegance or C18 3 Classic is 10V or 16 V Wire break between the batteries and E16 3 C19 3 Wire break between E13 1 and E13 2 C16 1 and C16 2 The light on the Power opt printed circu...

Страница 82: ...way 6 Drive lift downward a short distance 10 cm or so 7 Drive back up to the top 8 Finished The slow driving behavior must have disappeared now Explanation apparently sometimes this slow driving mod...

Страница 83: ...ch The encoders The joystick The armrest switches The foldable rail The charging The chair is out of level The chair leveling motor The remote control The fuse The tilt switch Powered swivel seat The...

Страница 84: ...84 Handicare Freecurve...

Страница 85: ......

Страница 86: ...ne France T 33 0 1 69 46 86 10 F 33 0 1 69 46 86 19 monte escaliers handicare fr Handicare GmbH Hausberger Stra e 16 32457 Porta Westfalica Deutschland T 49 0 571 97 33 98 55 F 49 0 571 97 33 98 56 da...