The seat inclines in program mode
•
Incorrect datacard
•
The calibration has not be done on the calibration point
•
The linking of the remotes have not be done on the calibration point
•
Wire break between K5-1/2/3/4 and the encoder
•
Wire break between K2-1/2/3/4 and the encoder
•
The traction motor encoder is faulty
•
The seat leveling motor is faulty
•
Wire break between K5-5 and K5-6 (standard between 40 - 70 Ω)
•
Wire beak between K5-7 and K5-8 (standard between 0 - 2 Ω)
•
Earth short at K5-1, K5-2
•
Low/weak batteries
•
Poor rail installation that has not been set to the correct angles on the drawing
The lift continues to function in the user mode, were it should operate in the traction mode
•
Wire break between K4-1/2/3 and the calibration switch (CS)
•
Earth short at K4-1, K4-2, K4-3
13
|
The seat inclines during the ride
14
|
Calibration
Technical manual