Handicare Freecurve
70
The LED remains off upon joystick operation
Connect the short-circuit connectors K6 and K9
A. The lift moves after operation of the direction switch (DS)
The fault is located in the chair
•
The key switch is off or faulty
•
The LED is faulty
•
Wire break between K6-1 and E1-1 (K6-1 and C1-1)
•
Wire break between K6-2 and E1-2 (K6-2 and C1-2)
•
Wire break between E10-1 and E10-2 (C13-1 and C13-2)
•
Wire break between E9-1 and E9-4 (C12-1 and C12-4)
•
Earth short at K6-1
B. The lift does not move after operation of the direction switch (DS)
The fault is located in the unit
No voltage between K3-9 and K3-10:
•
Wire break between the batteries and K3-9 or K3-10
•
The fuse has blown (check the wiring of the motor brakes K1-1 and K1-2 or K2-5 and K2-6)
Voltage between K3-9 and K3-10 around 26 V=:
•
Wire break between K4-13 and K6-2
•
Wire break between K4-14 and K6-1
•
Earth short at K4-14
The lift does not move when the LED is not functioning
3
|
The lift does not move in both directions