DAD 141.1 Technical Manual, Rev. 2.5 – April 2015
Page 21 of 54
7.10. Menu 8
– Data Communication
Remark: Activate a new setup with 1x Power OFF & ON !
8
Data Communication setup
(Menu 8.1 to 8.9)
8.1
Baud Rate for COM Port RS 422/485
(use the UP/DOWN buttons)
(command BR)
9600 Baud
19200 Baud
38400 Baud
57600 Baud
115200 Baud
8.2
Select RS 422 or RS 485
(use the UP/DOWN buttons)
422 = RS 422 Interface for single DAD 141.1 application
485 = RS 485 Interface for multiple DAD 141.1 application in a bus
8.3
Set Device Address COM Port (RS 422/485)
(command AD)
- Set device address for multi-
drop to 001 …
255
- Set device address for single point to point applications to 000
- Factory Default: 000
8.4
Select Auto-transmit mode
(use the UP/DOWN buttons)
gros -
Gross
value
(command SG)
net -
Net
value
(command SN)
AUEr - A
verage
value
(command SA)
SAP -
ADC value
ALL - Data string with
Gross, Net and Status
(command SW)
PEA -
Peak
value (Maximum)
(command SM)
HoLd - H
old
value
(command SH)
UALL -
Valley
value (Minimum)
(command SV)
PP -
Peak to Peak
value
(command SO)
oFF - set output "1"
OFF
8.5
Transmission delay Tx @ COM Port
(required for some PLCs)
(command TD)
-
Transmission delay from 000 … 25
5 milliseconds
8.6
IP-Address of Ethernet Interface
(command NA)
- in decimal notation per 3 characters
- Factory default:
192.168.0.100
8.6.x
Example for factory default - AAA.BBB.CCC.DDD
8.6.1 AAA
000
192
8.6.2 BBB
000
168
8.6.3 CCC
000
000
8.6.4 DDD
000
100