IMAGETEAM™ 4X00 Series Integration Manual
1 - 3
Imager Orientation
When the IT4X00 Series is mounted with the label pointing up, captured images appear right side up.
Connector Position and Flex Orientation
Connector
The interface connector is a Molex 0.30mm (.012") Easy-On™ Type Right Angle, SMT, ZIF, Bottom Contact Style Receptacle
part number 54393-2192. See
Interface Connector
on page 1-2 for details.
Connector Pinout
Pin
Signal
Description
1
Ground
Power and signal ground.
2
LED Current Control PWM
Input - Controls the LED current. A pulse width modulated signal based on a frequency of 7.5K Hz
reduces the current of the LED power supply. The relationship of current to duty cycle is inversely pro-
portional (the longer the duty cycle, the lower the current). Leave this pin unconnected if not using this
feature.
3
Ground
Power and signal ground.
4
Horizontal Sync (H Data Valid)
Output - Definition varies according to the setting of the image registers. For the configuration defined in
this document, this signal is used as a data valid window. Polarity of this signal is selectable in register
address 0x01, Bit 1. Hand Held Products setting is 1 = active high window.
5
Vertical Sync (V Data Valid)
Output - Definition varies according to the setting of the image registers. For the configuration defined in
this document, this signal is used as a data valid window. Polarity of this signal is selectable in register
address 0x01, Bit 2. Hand Held Products setting is 0 = active low window.
6
Aimer On
Input - Active high on this line enables the LED power supply and turns on the 2 aiming LEDs. This line
may be pulse width modulated many times per horizontal line (based on pixel clock) in order to reduce
power.
7
Illumination On
Input - Active high on this line enables the LED power supply and turns on the 4 illumination LEDs. This
line may be pulse width modulated many times per horizontal line (based on pixel clock) in order to
reduce power.
8
Power Enable
Input - Active high enables the imager. A low on this line places the imager in a power down state.
9
I
2
C Data (SDA)
Imager follows slave protocols with respect to this signal.
10
I
2
C Clock (SCL)
Imager follows slave protocols with respect to this signal.
Top
Flex
Содержание IMAGETEAM IT4000HD
Страница 4: ......
Страница 29: ...IMAGETEAM 4X00 Series Integration Manual 3 7 Optional Mounting Configuration for IT4000 Units Inches mm ...
Страница 30: ...3 8 IMAGETEAM 4X00 Series Integration Manual Standard Mounting Configuration for IT4100 Units Inches mm ...
Страница 31: ...IMAGETEAM 4X00 Series Integration Manual 3 9 Optional Mounting Configuration for IT4100 Units Inches mm ...
Страница 33: ...IMAGETEAM 4X00 Series Integration Manual 3 11 Standard Mounting Configuration for IT4300 Units Inches mm ...
Страница 34: ...3 12 IMAGETEAM 4X00 Series Integration Manual Optional Mounting Configuration for IT4300 Units Inches mm ...
Страница 36: ...3 14 IMAGETEAM 4X00 Series Integration Manual ...
Страница 42: ...4 6 IMAGETEAM 4X00 Series Integration Manual ...
Страница 46: ...5 4 IMAGETEAM 4X00 Series Integration Manual ...
Страница 48: ...A 2 IMAGETEAM 4X00 Series Integration Manual ...
Страница 50: ...B 2 IMAGETEAM 4X00 Series Integration Manual ...
Страница 52: ...C 2 IMAGETEAM 4X00 Series Integration Manual ...
Страница 54: ...D 2 IMAGETEAM 4X00 Series Integration Manual ...
Страница 55: ......
Страница 56: ... Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 4X00 IM Rev B 5 05 ...