HAMWORTHY HEATING LTD
12
WESSEX 100 M
500001080/F
Figure 8.12 Site Wiring Diagram
L
L
L
L
L
L
N
N
N
N
N
N
LO
C
KO
U
T V
O
LT
F
R
EE
CO
NT
AC
T C
O
N
N
EC
TI
O
N
S
O
VE
RHE
AT
V
O
LT
F
R
EE
CO
NT
AC
T C
O
N
N
EC
TI
O
N
S
CO
NT
AC
T C
O
N
N
EC
TI
O
N
S
NO
RM
AL
R
U
N V
O
LT
F
R
EE
NO
T UT
IL
IS
ED
TIME CLOCK
REMOTE
FUSED ISOLATOR
FU
S
ED
IS
OL
AT
O
R
FU
S
ED
IS
OL
AT
OR
FU
S
ED
IS
OL
AT
OR
FU
S
ED
IS
OL
AT
OR
FU
S
ED
IS
OL
AT
O
R
CONTROLS
CONTROLS
CONTACT
CONTACT
CONTACT
CONTACT
CONTACT
CONTACT
CONTROLS
CONTROLS
CONTROLS
CONTROLS
SAFETY INTERLOCK
INTERLOCK
BLR 1 ON/OFF
BLR 2 ON/OFF
BLR 3 ON/OFF
INTERLOCK
INTERLOCK
INTERLOCK
BLR 1 HIGH/OW
BLR 2 HIGH/OW
BLR 3 HIGH/OW
INTERLOCK
SAFETY
SEQUENCER
SEQUENCER
SEQUENCER
SAFETY
SAFETY
SAFETY
SEQUENCER
SEQUENCER
SEQUENCER
SAFETY
L
L
L
L
L
L
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
N
N
N
N
N
N
1
1
2
2
15
G1
G1
G1
G1
G1
G1
CN16
BOILER SITE WIRING TERMINALS
16
G2
G2
G2
G2
G2
G2
17
G3
G3
G3
G3
G3
G3
18
G4
G4
G4
G4
G4
G4
19
20
21
31
32
33
34
1) SINGLE BOILER INSTALLATION, ON/OFF OR HIGH/LOW OPERATION VIA REMOTE TIME CLOCK CONTROL.
2) MULTIPLE BOILER INSTALLATION, ON/OFF OR HIGH/LOW OPERATION VIA HAMWORTHY HEATING LIMITED MILTON BOILER SEQUENCE CONTROL.
NOTE: ROTARY SWITCH ‘SW1’ ON THE SEQUENCING INTERFACE MODULE - POSITIONS ‘1’ TO ‘9’ SETS THE BOILER FIRING ORDER.
3) MULTIPLE BOILER INSTALLATION, ON/OFF OR HIGH/LOW OPERATION VIA NON HAMWORTHY HEATING LIMITED BOILER SEQUENCE CONTROL.
NOTE: VOLT FREE CONTACT TERMINALS
NOT SHOWN FOR CLARITY.
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
BOILER PCB TO ‘SIM’
BOILER PCB TO ‘SIM’
LOW VOLTAGE
LOW VOLTAGE
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
230V AC 50Hz
VOLT FREE SIGNAL OUTPUTS
RATED UP TO 250V AC 5A
SUPPLY
SUPPLY
SUPPLY
SUPPLY
SUPPLY
SUPPLY
INTERFACE TERMINALS
INTERFACE TERMINALS
INPUTS/OUTPUTS
INPUTS/OUTPUTS
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
REMOTE CONTROL LOOPS.
NOTE: TERMINALS ‘G1’ AND ‘G3’ ARE
SUPPLIED WITH 230V AC.
MAINS VOLTAGE
BE FED
ONTO THESE TERMINALS!
MUST NOT
SOCKET TERMINALS
BOILER MAIN SITE WIRING TERMINALS - PLUG BRACKET
BOILER PCB PLUG/
SOCKET TERMINALS
BOILER PCB PLUG/
SOCKET TERMINALS
BOILER PCB PLUG/
SOCKET TERMINALS
BOILER PCB PLUG/
SOCKET TERMINALS
BOILER PCB PLUG/
SOCKET TERMINALS
BOILER MAIN SITE
WIRING TERMINALS
BOILER MAIN SITE
WIRING TERMINALS
BOILER MAIN SITE
WIRING TERMINALS
BOILER MAIN SITE
WIRING TERMINALS
BOILER MAIN SITE
WIRING TERMINALS
SEQUENCING INTERFACE MODULE TERMINALS
SEQUENCING INTERFACE MODULE TERMINALS
C
C
B
B
A
A
9
9
8
8
7
7
6
6
5
5
ROTARY SWITCH
ROTARY SWITCH
SW1
SW1
4
4
3
3
2
2
1
1
0
0
F
F
E
E
D
D
WIRING HARNESS
TO BOILER MAIN PCB
CONNECTOR ‘C1-C8’
WIRING HARNESS
TO BOILER MAIN PCB
CONNECTOR ‘C1-C8’
NOT
UTILISED
NOT
UTILISED
SEQUENCING INTERFACE MODULE
SEQUENCING INTERFACE MODULE
BOILER NUMBER 1
BOILER NUMBER 1
BOILER NUMBER 2
BOILER NUMBER 3
BOILER SITE WIRING TERMINALS
BOILER SITE WIRING TERMINALS
BOILER SITE WIRING TERMINALS
BOILER NUMBER 2
TO HAMWORTHY HEATING LIMITED
MILTON BOILER SEQUENCE CONTROL
(REFER TO MILTON INSTALLATION
MANUAL FOR FURTHER DETAILS)
BOILER PCB PLUG/
Содержание Wessex 100 M100