Hampton H35 Direct Vent Freestanding Gas Stove
19
Alternate
Horizontal
Termination Caps
Dura-Vent Basic
Horizontal Kit # 970
1 90
o
Elbow
1 Wall Thimble Cover
1 Horiz. Sq. Term. Cap
INSTALLATION
DURA-VENT TERMINATION KIT
Planning Your Dura-Vent
Installation
There are two basic types of Dura-Vent Direct
Vent System installations: horizontal termina-
tion and vertical termination. Confirm the max-
imum horizontal run and maximum vertical rise
from the diagrams on pages 12-16.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for 2 x 4 or 2 x 6 wall
construction.) Select the amount of vertical
rise desired for "vertical-to-horizontal" type
installations.
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire haz-
ard. Do not fill air spaces with insu-
lation.
The minimum clearance requirements between
the outer wall of the vent pipe and nearby
combustible surfaces is 1-1/4 inch. Be sure to
check the vent termination clearance require-
ments from decks, windows, soffits, gas
regulators, air supply inlets and public walk-
ways as specified in the Exterior Vent Ter-
minal Locations on page 9 and in your local
building codes.
To determine the length of vent pipe required
for vertical installations, measure the dis-
tance from the unit flue outlet to the ceiling, the
ceiling thickness, the vertical rise in an attic
or second storey, and allow for sufficient
vertical height above the roof line.
For multi-storey applications, fire stops are
required at each floor level. If an offset is
needed, additional pipe, elbows and sup-
ports will be required.
Do not exceed the maximum number of el-
bows. One 90
o
for horizontal terminations
and two 45
o
for vertical termination.
The FPI AstroCap
TM
is certified for installations using FPI venting systems as well as Simpson Dura-
Vent® and Direct Vent GS.
The FPI AstroCap
TM
is a proprietary trademark of FPI Fireplace Products International Ltd.
Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent
Co. Inc.