Hampton H35 Direct Vent Freestanding Gas Stove
INSTALLATION
Offset to Vertical Terminations
VENTING ARRANGEMENTS
Vertical Terminations Systems for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight
vertical and offset to vertical runs with vertical terminations.
Maximum two 45
o
elbows
.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below
show all allowable combinations of verti-
cal runs with horizontal terminations.
Maximum one 90
O
elbow (two 45
o
elbows
equal one 90
o
elbow).
Propane and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
The venting arrangements diagrammed below,
have a min. of 75% (flue loss) efficiency with
Fan Off, as required for manufactured homes.
(Actual efficiency may be as high as 85%)
May be installed in Manufactured (Mobile)
Homes after first sale.
ROTATING 45
O
ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS
1)
Remove all 4 screws that se-
cure the elbow to the unit using a
1/4" magnetic nut driver.
2)
Rotate the elbow 180
o
3)
Secure the elbow by securing
it with the 4 screws.
Remove all 4 screws
and washers