HG2200/HG2200AT Operator’s Manual
Electric Strike System (ESID)
100 - Systems and Equipment
Voltage Test
1. Place voltage limiter on something insulated from ground and unit (such as dry board or tire), but near
frame of unit.
2. Clip one lead to frame.
3. Clip other lead to one voltage limiter mount.
4. Move simulator switch to "voltage" and press test button.
5. Watch screen and lights above display on strike system.
•
All lights should turn on.
•
Alarm and strobe should turn on.
•
Voltage "V" should show 90% or higher.
IMPORTANT:
IT is normal for simulator voltage levels to drift below 100%.