background image

4

Änderungen vorbehalten

2. Safety Hints

STOP

 Attention!

 

Fitting or exchanging of an interface must not be 
made unless the oscilloscope is switched off and 
not connected to line (mains).

 

STOP

 Attention!

 

During operation the interface opening must be 
closed.

STOP

 Attention!

 

All interface connections are galvanically connected 
to the scope.  

STOP

  Measurement at high potentials is prohibited and 

endangers the scope, the interface and all equip-
ment connected to the interface. 

If the safety rules are disregarded, any damage to HAMEG In-
struments GmbH products will void the warranty. Consequently 
HAMEG Instruments GmbH will not take any responsibility for 
damage to people or equipment of other make. 

3. Interface Description

HO730 is a DUAL Interface that can be used either as an Ether-
net or as a USB 2.0 / 1.1 Interface. It is used with the HAMEG 
CombiScopes HM1008 and HM1508 for data transfer and 
oscilloscope control. Only one function (Ethernet or USB) - not 
both at the same time - can be activated (see item 6 “Interface 
Selection”).

3.1 Ethernet

The interface is equipped with an Ethernet type RJ-45 connector 
according to IEEE standard 802.3. For the direct connection 
with a host (PC) or indirect connection over a SWITCH, a doubly 
protected network cable (e.g. CAT.5, CAT.5e, CAT.5+, CAT.6 or 
CAT.7) is required, equipped with an Ethernet plug type the 
RJ-45 at each end. Either an uncrossed or a crossed network 
cable (cross over cable) can be used. 

3.2 USB

The interface is equipped with a Type A USB female connector. 
For direct connection with a host controller or an indirect con-
nection via a USB hub, a USB cable is required, equipped with 
Type B male connector one end and a Type A male connector 
at the other..

 

4. Oscilloscope Firmware

4.1  It is absolutely necessary to check the oscilloscope fi rmware 

version before fi tting the Interface HO730. The fi rmware 
version already on the scope is displayed after switching 
on if “Quick Start” is off. The “Quick Start” function can 
be changed after pressing the SETTINGS pushbutton and 
calling “Misc.”. Alternatively the fi rmware version of the 
oscilloscope can be found in the menu „Software“ by ope-
ration of the PROBE ADJ key 

>

 menu „Information“ 

>

 menu 

„Software“ (MC-Version:).

4.2  If the fi rmware version is 04.000-yy.yyy or higher, continue 

the interface fi tting as described under item 5 (Interface 
Fitting Instruction). In the case of fi rmware versions below 
04.000-yy.yyy, HO730 will not be recognised and a fi rmware 
update is required as described under item 4.3.

4.3  In case of a fi rmware version below 04.000-yy.yyy, please 

download the current fi rmware at www.hameg.com from the 
Internet and update the oscilloscope. The fi rmware can be 
found and downloaded under: Products 

>

 Oscilloscopes 

>

 

(oscilloscope type) 

>

 Software/Firmware (below the oscil-

loscope picture) 

>

 Firmware_HMxxx_Vxxx.zip. 

After receiving the current fi rmware and its installation instruc-
tion, the fi rmware installation must be done via the RS-232 
interface HO710 or the RS-232 port of the interface HO720. If 
the current fi rmware is installed, future updates can also be 
made over the USB port of the interface HO730.

 

Type A   

Type B

G e n e r a l  h i n t s          

Содержание HO730

Страница 1: ...E T H E R N E T U S B I N T E R F A C E H O 7 3 0 Installation guidelines English...

Страница 2: ...nditions in individual cases HAMEG Instruments GmbH KONFORMIT TSERKL RUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACI N DE CONFORMIDAD Hersteller Manufacturer Fabricant Fabricante HA...

Страница 3: ...ruction 5 5 1 Removing the existing interface 5 5 2 Fitting the interface HO730 5 6 Interface Selection 6 7 USB Driver Installation 7 7 1 Installation under Windows XP 7 8 Ethernet con guration 9 8 1...

Страница 4: ...e is equipped with a Type A USB female connector For direct connection with a host controller or an indirect con nection via a USB hub a USB cable is required equipped with Type B male connector one e...

Страница 5: ...of the oscilloscope to equalise potentials between oscilloscope and your body Maintain this connection during the tting removing Only touch the interface at its mounting panel 5 1 Removing the existi...

Страница 6: ...activated With the activating of Ethernet the menu option Parameter also ap pears additional in the Readout which the Ethernet interface parameter settings made possible see section 8 Reference The ho...

Страница 7: ...splayed Only in this case the USB Driver must be installed The USB Driver is located in the directory HO730_D2xx_Dri ver 7 1 Installation under Windows XP 7 1 1 Please choose No not this time and clic...

Страница 8: ...7 1 3 4 After the selected path is displayed click Next 7 1 4 Thereafter the Hardware Installation window is displa yed showing a warning to continue the installation procedure As this warning is irr...

Страница 9: ...s is used as network IP address and the last IP address is used as Broadcast IP address in each case two IP addresses have to be taken off from the number of possible host addresses see table 1 Privat...

Страница 10: ...on control to the desired value The menu option Save in the Readout saves the preset interface parameters by the oscilloscope and or determined automatically after press the menu option Save with acti...

Страница 11: ...he input eld Subnet mask please enter from your or from a network administrator spe ci ed subnet mask for the PC e g 255 255 255 0 In the input eld Default gateway please enter your or from a network...

Страница 12: ...the host PC If the connection over further network elements e g switches routers network servers etc is used examine if necessary these further connections as well as the presets of the appropriate n...

Страница 13: ...e found in the Internet www hameg com for downloading and updating your PC The path of the software is Products Oscilloscopes oscilloscope type Software Firmware below the oscilloscope picture Softwar...

Страница 14: ...14 Subject to change without notice...

Страница 15: ...15 nderungen vorbehalten A p p l i c a t i o n...

Страница 16: ...riestra e 6 A Rohde Schwarz Company D 63533 Mainhausen registered trademark Tel 49 0 61 82 800 0 DQS Certi cation DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales hameg de authorized...

Отзывы: