background image

2

Änderungen vorbehalten

G e n e r a l   i n f o r m a t i o n   r e g a r d i n g   t h e   C E   m a r k i n g          

General information regarding the CE marking

HAMEG instruments fulfi ll the regulations of the EMC directive. The 
conformity test made by HAMEG is based on the actual generic- and 
product standards. In cases where different limit values are applicable, 
HAMEG applies the severer standard. For emission the limits for 
residential, commercial and light industry are applied. Regarding the 
immunity (susceptibility) the limits for industrial environment have 
been used.

The measuring- and data lines of the instrument have much infl uence 
on emmission and immunity and therefore on meeting the acceptance 
limits. For different applications the lines and/or cables used may 
be different. For measurement operation the following hints and 
conditions regarding emission and immunity should be observed:

1. Data cables
For the connection between instruments resp. their interfaces and 
external devices, (computer, printer etc.) suffi ciently screened cables 
must be used. Without a special instruction in the manual for a reduced 
cable length, the maximum cable length of a dataline must be less than 
3 meters and not be used outside buildings. If an interface has several 
connectors only one connector must have a connection to a cable.
Basically interconnections must have a double screening. For IEEE-bus 
purposes the double screened cables HZ72S and HZ72L from HAMEG 
are suitable.

2. Signal cables
Basically test leads for signal interconnection between test point and 
instrument should be as short as possible. Without instruction in the 
manual for a shorter length, signal lines must be less than 3 meters 
and not be used outside buildings.
Signal lines must screened (coaxial cable - RG58/U). A proper ground 
connection is required. In combination with signal generators double 
screened cables (RG223/U, RG214/U) must be used.

3. Infl uence on measuring instruments.
Under the presence of strong high frequency electric or magnetic fi elds, 
even with careful setup of the measuring equipment an infl uence of 
such signals is unavoidable.
This will not cause damage or put the instrument out of operation. Small 
deviations of the measuring value (reading) exceeding the instruments 
specifi cations may result from such conditions in individual cases.

HAMEG Instruments GmbH

KONFORMITÄTSERKLÄRUNG

DECLARATION OF CONFORMITY
DECLARATION DE CONFORMITE

DECLARACIÓN DE CONFORMIDAD

Hersteller / Manufacturer / Fabricant / Fabricante: 
HAMEG Instruments GmbH · Industriestraße 6 · D-63533 Mainhausen 

Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt 
The HAMEG Instruments GmbH herewith declares conformity of the product 
HAMEG Instruments GmbH déclare la conformite du produit 
HAMEG Instruments GmbH certifi ca la conformidad para el producto

Bezeichnung:  

Ethernet/USB-Interface

Product name:  

Ethernet/USB Interface

Designation: Interface 

Ethernet/USB

Descripción: Interfaz 

Ethernet/USB

Typ / Type / Type / Tipo: 

HO730

mit / with / avec / con: 

HM1008, HM1508, HM1508-2, HM2008

Optionen / Options / 
Options / Opciónes: 

mit den folgenden Bestimmungen / with applicable regulations /  
avec les directives suivantes / con las siguientes directivas:

EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG 
EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC 
Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE 
Directiva EMC 89/336/CEE enmendada por 91/263/CEE, 92/31/CEE

Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG 
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE
Directiva de equipos de baja tensión 73/23/CEE enmendada por 93/68/EWG

Angewendete harmonisierte Normen / Harmonized standards applied / 
Normes harmonisées utilisées / Normas armonizadas utilizadas:

Sicherheit / Safety / Sécurité / Seguridad:

EN 61010-1:2001 / IEC (CEI) 1010-1:2001
Überspannungskategorie / Overvoltage category / Catégorie de surtension / 
Categoría de sobretensión: II

Verschmutzungsgrad / Degree of pollution / Degré de pollution / Nivel de 
polución: 2

Elektromagnetische Verträglichkeit / Electromagnetic compatibility / 
Compatibilité électromagnétique / Compatibilidad electromagnética: 

EN 61326-1/A1: Störaussendung / Radiation / Emission: Tabelle / table / 
tableau 4; Klasse / Class / Classe / classe B. 

Störfestigkeit / Immunity / Imunitee / inmunidad: 
Tabelle / table / tableau / tabla A1. 

EN 61000-3-2/A14: Oberschwingungsströme / Harmonic current emissions 
/ Émissions de courant harmonique / emisión de corrientes armónicas: 
Klasse / Class / Classe / clase D.

EN 61000-3-3: Spannungsschwankungen u. Flicker / Voltage fl uctuations 
and fl icker / Fluctuations de tension et du fl icker / fl uctuaciones de tensión 
y fl icker.

Datum / Date / Date / Fecha   
26. 09. 2006
 

Unterschrift / Signature / Signatur / Signatura

 Manuel 

Roth

 Manager
 

 

 

 

Содержание HO730

Страница 1: ...E T H E R N E T U S B I N T E R F A C E H O 7 3 0 Installation guidelines English...

Страница 2: ...nditions in individual cases HAMEG Instruments GmbH KONFORMIT TSERKL RUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACI N DE CONFORMIDAD Hersteller Manufacturer Fabricant Fabricante HA...

Страница 3: ...ruction 5 5 1 Removing the existing interface 5 5 2 Fitting the interface HO730 5 6 Interface Selection 6 7 USB Driver Installation 7 7 1 Installation under Windows XP 7 8 Ethernet con guration 9 8 1...

Страница 4: ...e is equipped with a Type A USB female connector For direct connection with a host controller or an indirect con nection via a USB hub a USB cable is required equipped with Type B male connector one e...

Страница 5: ...of the oscilloscope to equalise potentials between oscilloscope and your body Maintain this connection during the tting removing Only touch the interface at its mounting panel 5 1 Removing the existi...

Страница 6: ...activated With the activating of Ethernet the menu option Parameter also ap pears additional in the Readout which the Ethernet interface parameter settings made possible see section 8 Reference The ho...

Страница 7: ...splayed Only in this case the USB Driver must be installed The USB Driver is located in the directory HO730_D2xx_Dri ver 7 1 Installation under Windows XP 7 1 1 Please choose No not this time and clic...

Страница 8: ...7 1 3 4 After the selected path is displayed click Next 7 1 4 Thereafter the Hardware Installation window is displa yed showing a warning to continue the installation procedure As this warning is irr...

Страница 9: ...s is used as network IP address and the last IP address is used as Broadcast IP address in each case two IP addresses have to be taken off from the number of possible host addresses see table 1 Privat...

Страница 10: ...on control to the desired value The menu option Save in the Readout saves the preset interface parameters by the oscilloscope and or determined automatically after press the menu option Save with acti...

Страница 11: ...he input eld Subnet mask please enter from your or from a network administrator spe ci ed subnet mask for the PC e g 255 255 255 0 In the input eld Default gateway please enter your or from a network...

Страница 12: ...the host PC If the connection over further network elements e g switches routers network servers etc is used examine if necessary these further connections as well as the presets of the appropriate n...

Страница 13: ...e found in the Internet www hameg com for downloading and updating your PC The path of the software is Products Oscilloscopes oscilloscope type Software Firmware below the oscilloscope picture Softwar...

Страница 14: ...14 Subject to change without notice...

Страница 15: ...15 nderungen vorbehalten A p p l i c a t i o n...

Страница 16: ...riestra e 6 A Rohde Schwarz Company D 63533 Mainhausen registered trademark Tel 49 0 61 82 800 0 DQS Certi cation DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales hameg de authorized...

Отзывы: