Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
1
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
HMO352x, HMO2524
HMO72x ... HMO202x
Firmware Version: 03.00 and later
English
:ACQuire
:CHAN1OFFSet
:DISPlay
:HCOPy
*ESR?
*OPC?
:LOGic:SIZE
:MEASure
:POD1
:SYSTem
*SRE?
S C P I P r o g r a m m e r s M a n u a l
H M O S e r i e s
SCPI Commands HMC8012
[SENSe:]CURRent[:DC]:RANGe[:UPPer]? [{MIN|MAX}]
Returns the state of the DC I measurement function range.
Return values:
<Range>
20mA, 200mA, 2A, 10A
MIN: 2.00000000E-02
MAX: 1.0001
DEFault: 2.00000000E-02
DC V configuration commands
CONFigure[:VOLTage][:DC] [{<Range>|AUTO|MIN|MAX|DEF}] ................................. 44
[SENSe:]VOLTage[:DC]:NULL[:STATe] {ON|OFF} ........................................................ 44
[SENSe:]VOLTage[:DC]:NULL[:STATe]? ...................................................................... 45
[SENSe:]VOLTage[:DC]:NULL:VALue {<Value>|MIN|MAX} ........................................ 45
[SENSe:]VOLTage[:DC]:NULL:VALue? [{MIN|MAX}]................................................... 45
[SENSe:]VOLTage[:DC]:RANGe:AUTO <Mode> ........................................................ 45
[SENSe:]VOLTage[:DC]:RANGe:AUTO? ..................................................................... 45
[SENSe:]VOLTage[:DC]:RANGe[:UPPer] {<Range>|MIN|MAX|DEF} .......................... 46
[SENSe:]VOLTage[:DC]:RANGe[:UPPer]? [{MIN|MAX}] .............................................. 46
[SENSe:]VOLTage[:DC]:ZERO:AUTO <Mode> ..........................................................46
[SENSe:]VOLTage[:DC]:ZERO:AUTO? ........................................................................ 46
CONFigure[:VOLTage][:DC] [{
<
Range
>
|AUTO|MIN|MAX|DEF}]
Configures the instrument for DC V measurements, but does not initiate a measurement. Use the READ? command to
query the DC V measurement value with specified range or the CONF? command to query the DC V function configu-
ration.
Parameter:
<Range>
400mV, 4V, 40V, 400V, 1000V
AUTO:
Auto range
MIN: 400mV
MAX: 1000V
DEFault: 400mV
If the input signal is greater than can be measured on the selected range (manual ranging),
the instrument returns 9.9037.
*RST: AUTO
[SENSe:]VOLTage[:DC]:NULL[:STATe] {ON|OFF}
Turns the null function for DC V measurement function on or off.
Parameters:
<State>
ON | OFF
ON:
Null function of DC V measurement function is activated
OFF:
Null function of DC V measurement function is disabled
*RST: OFF