1
1
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
1
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
HMO352x, HMO2524
HMO72x ... HMO202x
Firmware Version: 03.00 and later
English
:ACQuire
:CHAN1OFFSet
:DISPlay
:HCOPy
*ESR?
*OPC?
:LOGic:SIZE
:MEASure
:POD1
:SYSTem
*SRE?
S C P I P r o g r a m m e r s M a n u a l
H M O S e r i e s
SCPI Commands HMC8012
2.4
Trigger commands
TRIGger:COUNt {<Count>|MIN|MAX|DEFault} .......................................................... 26
TRIGger:COUNt? [MINimum|MAXimum] .................................................................. 26
TRIGger:INTerval {<Seconds>|MIN|MAX|DEF} .......................................................... 26
TRIGger:INTerval? [{MIN|MAX}] ................................................................................. 27
TRIGger:LEVel {<Level>|MIN|MAX|DEF} ................................................................... 27
TRIGger:LEVel? [{MIN|MAX}] ..................................................................................... 27
TRIGger:LEVel:MODe {CONTinue | ABOVe|BELow} .................................................. 27
TRIGger:LEVel:MODe? .............................................................................................. 27
TRIGger:MODE {<Mode>} ......................................................................................... 28
TRIGger:MODE? ........................................................................................................ 28
TRIGger:COUNt {
<Count>
|MIN|MAX|DEFault}
Selects the number of triggers for the single trigger mode before returning to the „idle“ trigger state.
Parameters:
<Count>
Trigger count value in single trigger mode.
<Count>:
1 to 50,000
MIN: 1
MAX: 50,000
DEFault: 1
*RST:
1
TRIGger:COUNt? [MINimum|MAXimum]
Returns the trigger count of the single trigger mode.
Return values:
<Count>
1 to 50,000
MIN: 1.0E+00
MAX: 5.04
TRIGger:INTerval {
<
Seconds
>
|MIN|MAX|DEF}
Selects the trigger time interval for the single trigger mode before returning to the „idle“ trigger state.
Parameters:
<Interval>
Trigger time interval value in single trigger mode.
<Seconds>: 0 to 3,600s
MIN: 0s
MAX: 3,600s
DEFault: 0s
*RST:
0.0E+00s