58
HAMEG Instruments GmbH • Industriestr. 6 • D-63533 Mainhausen • Deutschland
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen, Dipl.-Ing. Andre Vander Stichelen • AG Offenbach am Main HRB 41200
1
1
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
1
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
HMO352x, HMO2524
HMO72x ... HMO202x
Firmware Version: 03.00 and later
English
:ACQuire
:CHAN1OFFSet
:DISPlay
:HCOPy
*ESR?
*OPC?
:LOGic:SIZE
:MEASure
:POD1
:SYSTem
*SRE?
S C P I P r o g r a m m e r s M a n u a l
H M O S e r i e s
SCPI Commands HMC8012
ADC rate configuration commands
[SENSe:]ADCRate {SLOW | MEDium | FAST}
Selects the ADC rate for the activated measurement function. The reading rate per second of the ADC rate function is
depending on the activated measurement function.
Parameters:
<Function>
SLOW | MEDium | FAST
*RST: SLOW
[SENSe:]ADCRate?
Returns the ADC rate for the activated measurement function.
Return values:
<Function>
SLOW | MED | FAST
Miscellaneous
CONFigure? ............................................................................................................... 58
[SENSe:]FUNCtion[:ON] <Function> ......................................................................... 58
[SENSe:]FUNCtion[:ON]? ........................................................................................... 59
CONFigure?
Returns the actual instrument configuration.
Example:
TEMP, PT100, RTD
Usage:
Query only
[SENSe:]FUNCtion[:ON]
<
Function
>
Selects the measurement function.
Parameters:
<Function>
VOLTage[:DC]
DC V measurement function
VOLTage:AC
AC V measurement function
CURRent[:DC]
DC I measurement function
CURRent:AC
AC I measurement function
RESistance
2-wire resistance measurement function
FRESistance
4-wire resistance measurement function
FREQuency[:VOLTage]
Frequency measurement function in AC V mode
FREQuency:CURRent
Frequency measurement function in AC I mode
CONTinuity
Continuity measurement function
DIODe
Diode
measurement
function
SENSor
Sensor
measurement
function
*RST:
VOLT[:DC]
Example:
FUNC VOLT:AC