background image

15

Subject to change without notice

coefficient into calibrated condition and activates the
attenuator function. The previous vernier setting will not be
stored.
The

 CHI 

pushbutton can also be pressed simultaneously with

the

 DUAL(19) 

button.

 Please note item (19)

.

(19) DUAL - XY 

– Pushbutton with multiple functions.

DUAL mode:

Briefly pressing this button switches over to DUAL mode.
Both deflection coefficients are then displayed. The previous
trigger setting stays as it was, but can be changed.
All controls related to both channels are active, if the inputs

(28) 

and

 (32) 

are not set to

 GD (30) (34)

. Whether alternated

or chopped channel switching is present depends on the
actual time base setting, and is displayed in the readout.

ALT

displayed in the readout, indicates alternate channel
switching. After each time base sweep the instrument
internally switches over from channel I to channel II and vice
versa. This channel switching mode is automatically selected
if any time coefficient from 200µs/div to 50ns/div is active.

CHP

indicates chopper mode, whereby the channel switching
occurs constantly between channel I and II during each
sweep. This channel switching mode occurs when any time
base setting between 500ms/div and 500µs/div has been
chosen.
The actual channel switching can be changed to the opposite
mode by briefly pressing both

 CHI (18) 

and 

DUAL (19)

simultaneously. If afterwards the time coefficient is changed,
the channel switching is automatically set to the time
coefficient related mode.

ADD mode:

Addition mode can be selected by briefly pressing the 

DUAL

(19) 

and

 CHII (22) 

buttons simultaneously. Whether the

algebraic sum (addition) or the difference (subtraction) of both
input signals is displayed, depends on the phase relationship
and the

 INV (30) (34) 

setting(s). As a result both signals are

displayed as one signal. For correct measurements the
deflection coefficients for both channels must be equal.

The readout indicates this mode by a “+” sign located
between both channel deflection coefficients. While the
trigger mode is not affected, the trigger point symbol is
switched off. The Y-position of the signal can be influenced
by both

 Y-POS 

controls

 (9) 

and

 (11)

.

XY mode:

This mode can be switched on or off by pressing and holding
the

 DUAL 

button

 (19)

.

In

 XY 

mode the deflection coefficients are displayed as 

“X...”

for channel I and

 “Y...” 

for channel II, followed by 

“XY”

. Except

the cursor lines which may be active, all other readout
information including the trigger point symbol are switched
off. In addition to all trigger and time base related controls,
the

 Y-POS. I (9) 

knob and 

INV (30) 

button are deactivated.

For X position alteration, the

 X-POS. (15) 

knob can be used.

(20) TRIG. - ALT

 – Pushbutton with double function for trigger

source selection and associated LEDs.
The button and the LEDs are deactivated if line (mains)
triggering is selected or XY operation is chosen.

With the aid of this button, the trigger source can be chosen.
There are three trigger sources available: channel I, channel
II (both designated as internal trigger sources) and the

 TRIG.

EXT. (35) 

input for external triggering.

The availability of the internal sources depends on the actual
channel mode. The actual setting is indicated by the
associated LED(s). Briefly pressing the button switches over
in the following sequence:
I - II - EXT - I in DUAL and ADD (addition) mode,
I - EXT - I

if mono channel I is present,

II - EXT - II

under mono channel II conditions.

Each condition is indicated by the associated LED and
displayed by the readout (

“TR:Y1...”, “TR:Y2...” 

and

“TR:EXT...”

). The trigger point symbol is switched off in

external trigger condition.

ALT:

Pressing and holding the button selects alternate triggering
in

 DUAL 

mode. Under these conditions both I and II LEDs

are lit and the readout displays

 “TR:ALT...”

. As alternate

triggering requires alternate channel operation, alternate
channel switching is set automatically. A change of the time
coefficient then has no affect regarding the channel switching
mode. In addition to the deflection coefficients display,

 “ALT”

is displayed by the readout instead of

 “CHP”

. In alternate

trigger mode the trigger point symbol is switched off.

Alternate triggering

 is not available or automatically

switched off under the following conditions:

– ADD 

(addition) mode,

– alternate 

(A & B) time base mode,

– B 

time base mode,

– TVL, TVF 

and

 line 

(mains) trigger coupling.

(21) VOLTS/DIV. 

– This control knob for channel II has a double

function.
The following description relates to the input attenuator
function (VAR LED dark). The vernier function is active if the
VAR LED is lit (see 

VAR

 under item 

(22)

).

Turning the control knob clockwise increases the sensitivity
in a 1-2-5 sequence and decreases it if turned in the opposite
direction (ccw.). The available range is from 1mV/div up to
20V/div. The knob is automatically switched inactive if the
channel related to it is switched off, or if the input coupling is
set to

 GD 

(ground).

Controls and Readout

MADE IN GERMANY

A/ALT.

DEL.TRIG

TRS

PUSH
BOTH

PUSH
LONG

VAR.

B

CH I

CH II

DEL.POS.

ADD

CHP.

VAR.

VAR.

DUAL

X-Y

VOLTS / DIV.

VOLTS / DIV.

TIME / DIV.

5V 

       1mV

5V 

       1mV

0.5s 

       20ns

TRIG. MODE

TRIG.

ALT

CHI

AC
DC

HF

NR

LF

TVL
TVF

CHII
EXT

Y-POS. I

Y-POS. II

LEVEL

X-POS.

NM

AT

X-

MAG.

63

-K

304-0040/

00

55

BWL

BW

LIMIT

VAR

VAR

TR

NM

HO

VAR

x10

 

17

18

19

20

22

23

24

25

26

27

21

9

10

12

11

14

16

15

13

8

Содержание HM 2005

Страница 1: ...TRIG EXT INP max 100 Vp Z x1 x10 INV x1 x10 200 MHz ANALOG OSCILLOSCOPE HM2005 Instruments TRK CAT I GD AC DC GD CH I CH II DEL POS ADD CHP VAR VAR DUAL X Y VOLTS DIV VOLTS DIV TIME DIV 5V 1mV 5V 1mV...

Страница 2: ...Subject to change without notice 2 M A N U A L H A N D B U C H M A N U E L...

Страница 3: ...X Y Operation 24 Phase comparison with Lissajous figures 24 Phase difference measurement in DUAL mode Yt 24 Measurement of amplitude modulation 25 Triggering and Time Base 25 Automatic Peak value Trig...

Страница 4: ...radiation The device under test as well as the oscilloscope may be effected by such fields Although the interior of the oscilloscope is screened by the cabinet direct radiation can occur via the CRT g...

Страница 5: ...y modulation max 5V TTL Line Voltage Power consumption 100 240V AC 10 approx 43Watt 50 60Hz Min Max ambient temperature 10 C 40 C Protective system Safety class I IEC1010 1 Weight approx 5 9kg Size W...

Страница 6: ...ve neutral have been tested against insulation breakdown with 2200V DC The mains line plug shall only be inserted in a socket outlet provided with a protective earth contact The protective action must...

Страница 7: ...arly failures are detected by this method In the case of shipments by post rail or carrier the original packing must be used Transport damages and damage due to gross negligence are not covered by the...

Страница 8: ...can only be measured with DC coupling The input coupling is selectable by the AC DC pushbutton The actual setting is displayed in the readout with the symbol for DC and the symbol for AC coupling Amp...

Страница 9: ...for example only the residual ripple of a high voltage is to be displayed on the oscilloscope a normal x10 probe is sufficient In this case an appropriate high voltage capacitor approx 22 68nF must b...

Страница 10: ...the rise time of the probe e g 1 4ns If ttot is greater than 16ns then ttot can be taken as the rise time of the pulse and calculation is unnecessary Calculation of the example in the figure above re...

Страница 11: ...refore of quite special importance with a x100 attenuation probe which usually has a voltage rating of max 1200 V DC peak AC A capacitor of corresponding capacitance and voltage rating may be connecte...

Страница 12: ...can be adjusted with a small screwdriver please note trace rotation TR 6 FOCUS This control knob effects both the trace and the readout sharpness 7 SAVE RECALL The instrument contains 9 non volatile...

Страница 13: ...nction is practically ineffective in this settings 11 Y POS II Control knob The vertical trace position of channel II can be set with this control knob In ADD addition mode both Y POS I and Y POS II c...

Страница 14: ...id of the X POS control As the X expansion results in a higher time base speed lower time deflection coefficient all time and frequency relevant information in the readout is switched over The X magni...

Страница 15: ...e related controls the Y POS I 9 knob and INV 30 button are deactivated For X position alteration the X POS 15 knob can be used 20 TRIG ALT Pushbutton with double function for trigger source selection...

Страница 16: ...DC trigger coupling Both settings are indicated by the NM 12 and the DC TRIG MODE LED 23 The previous trigger settings regarding the A time base remain unchanged In some trigger modes such as alterna...

Страница 17: ...ce This sector indicates the signal part which is displayed by the B time base The intensified segment can be shifted horizontally by the DEL POS 24 control knob continuously if the B time base is ope...

Страница 18: ...ground connection is galvanically connected to the instrument ground and consequently to the safety earth contact of the line mains plug 29 AC DC Pushbutton with two functions Input coupling Briefly...

Страница 19: ...and the square wave calibrator with their outputs 36 MENU Pushbutton Pressing and holding this pushbutton activates the display of the MAIN MENU It contains the submenus TEST CALIBRATE and SETUP The i...

Страница 20: ...t be taken into account In case of x10 10 1 probes the probe factor can be automatically included see item 29 and 33 If a x100 100 1 probe is used switch to the probe symbol 10 1 off if displayed Then...

Страница 21: ...on was called inadvertently the proceeding can be cancelled by pressing the AUTOSET 3 pushbutton 3 AUTOSET 3 pushbutton return function Each time the AUTOSET pushbutton is pressed the menu is switched...

Страница 22: ...s should be used Particular care is required when a single spot is displayed as a very high intensity setting may cause damage to the fluorescent screen of the CRT Switching the oscilloscope off and o...

Страница 23: ...the same value as during the 1kHz adjustment Probes other than those mentioned above normally have a larger tip diameter and may not fit into the calibrator output Whilst it is not difficult for an ex...

Страница 24: ...measuring the distances a and b on the screen is quite simple with the following formula and a pocket calculator with trigonometric functions Apart from the reading accuracy the signal height has no i...

Страница 25: ...ed oscillation F 1 MHz f 1 kHz m 50 UT 28 3 mVrms Oscilloscope setting for a signal according to figure 2 Y CH I 20mV div AC TIME DIV 0 2ms div Triggering Normal with LEVEL setting internal or externa...

Страница 26: ...displayed threshold can be stated as vertical display height in div at which the time base generator starts the display is stable and the trigger indicator LED lights or flashes The internal trigger t...

Страница 27: ...visible TVL On the 10 s div setting and line TV triggering selected approx 1 lines are visible Those lines originate from the odd and even fields at random The sync separator circuit also operates wit...

Страница 28: ...ot coinciding with the slope selection setting The trigger coupling selection can also be used in external triggering mode Trigger indicator TR The following description applies to the TR LED Please n...

Страница 29: ...ng this function is part of the section Controls and Readout paragraph AUTOSET 2 As also mentioned in that section all controls are electronically selected with the exception of the POWER and calibrat...

Страница 30: ...s and transistors resistors capacitors and inductors Certain tests can also be made to integrated circuits All these components can be tested individually or in circuit provided that it is unpowered T...

Страница 31: ...des Possibly only a small portion of the knee is visible Zener diodes always show their forward knee and depending on the test voltage their zener breakdown forms a second knee in the opposite directi...

Страница 32: ...lvanically connected with the oscilloscope and subsequently with protective safety earth potential Measurement on a high level reference potential is not permitted and endangers operator oscilloscope...

Страница 33: ...switched off the RM LED 3 is dark Please note A minimum time must elapse between the commands RM 1 remote on and RM 0 remote off and vice versa The time can be calculated with the formula tmin 2x 1 ba...

Страница 34: ...ANALOG OSCILLOSCOPE HM2005 Instruments TRK CAT I GD AC DC GD CH I CH II DEL POS ADD CHP VAR VAR DUAL X Y VOLTS DIV VOLTS DIV TIME DIV 5V 1mV 5V 1mV 0 5s 20ns TRIG MODE TRIG ALT CHI AC DC HF NR LF TVL...

Страница 35: ...35 Subject to change without notice M A N U A L H A N D B U C H M A N U E L...

Страница 36: ...0 Telefax 0 61 82 800 100 E mail sales hameg de Printed in Germany Oscilloscopes Multimeters Counters Frequency Synthesizers Generators R and LC Meters Spectrum Analyzers Power Supplies CurveTracers T...