9
EcoloAir Operation, Maintenance & Service Manual
EA
OMSI/0
1
2
0
09/re
v1/EN
ODOR CONTROL
To replace a 5 Gallon bottle of Ecolo Scentry Solution
1. Open enclosure cabinet door by unscrewing the two lock bolts.
2. Remove the cap from the empty bottle.
3. Pull the dip tube assembly out of the empty bottle.
4. Remove the empty bottle from the cabinet.
5.
Refi ll bottle or replace with a new bottle.
6. Place the bottle into the cabinet.
7. Replace the dip tube or low level control device assembly into the bottle. Make sure the dip
tube reaches the bottom of the bottle.
8. Place cap on bottle neck.
9. Close the cabinet door and lock with locking bolts.
The Ecolo Unit is set to operate either on a continuous spray or on an intermittent spray cycle while
fan is running.
A switch is provided on the Ecolo Control Panel to be activated for the desired application.
The unit when shipped, will be set for a 20 second spray every 1 minute. This can be adjusted in the
fi eld to give the required setting for each particular installation.
SETTING ECOLO TIME ON AND TIME OFF CYCLE
The Ecolo Unit is set to operate either
1. To set the Ecolo time on, press the “T-ON” button on the electronic text display once.
Currently set value of ECOLO T-ON in seconds is displayed.
2. Press the “ENTER” button once, a blinking cursor appears.
3. Use the “
ST
” up and down arrows to set desired time for ecology ON cycle.
Press “ENTER” again to fi nish.
4. To set the Ecolo time off, press the “T-OFF” button on the electronic text display once.
Currently set value of ECOLO T-OFF in seconds is displayed.
5. Press the “ENTER” button once, a blinking cursor appears.
6. Use the “
ST
” up and down arrows to set desired time for ecology OFF cycle.
Press “ENTER” again to fi nish.