Instruction Manual PSx3xxPL
45
5.3
STO Data
Performance Level
(DIN EN ISO 13849)
“c”
Safety Integrity Level
(DIN EN 61800)
SIL 1
STO input level
Low <5 V; High >15 V
No STO EVENT (normal operation)
High level with test pulses (OSSD, optional)
STO Event (Emergency-Stop)
Low level
Detailed information about the technical data of the STO functionality
can be read into the safety manual
5.4
Physical data
positioning range
250 usable rotations, no mechanical limits
measuring system has a span of 256 turns, minus 3
turns security stock at upper and lower range limit
torsional rigidity
(angle of rotation when switching from
operation without backlash to
maximum torque)
max. 0.2°
gear backlash
(without spindle compensation run)
max. 0.5°
spindle lash compensation
automatic loop after every positioning run (may be
deactivated)
output shaft
PSE30x-8,
PSE31x-8
8H9 hollow shaft with
adjustable collar
PSE30x-14, PSE31x-14,
PSE32x, PSE33x
14H7 hollow shaft with
adjustable collar
PSE31xx,
14H7 hollow shaft with
clamp and feather key
PSS3xx-8,
PSW3xx-8
8H9 hollow shaft with
adjustable collar or
8h8 solid shaft
PSS3xx-14,
PSW3xx-14
14H7 hollow shaft with
adjustable collar or
14h8 solid shaft
recommended diameter of the spindle
head
according to the hollow shaft diameter with an
interference fit of h9
maximum radial force
40 N
maximum axial force
20 N
dimensions (l x w x h)
see catalog data on our website
weight (approx.)
PSx30x-8
650 g
PSx30x-14, PSx32x
1200 g
PSx31x-8
700 g
PSx31x-14, PSx33x
700 g
PSE31xx
1200 g
For additional specifications and dimension drawings, please visit our website at
https://www.halstrup-walcher.de/en/products/drive-technology/
7100.006754B_PSx3xxPL-STO.docx
03/2022 Re/Me/RH
Содержание PS-3 Series
Страница 46: ...Instruction Manual PSx3xxPL 46 6 Certificate of Conformity ...
Страница 47: ...Instruction Manual PSx3xxPL 47 ...