Instruction Manual PSx3xxEC
8
2.5
Pin assignment
Please take care that the mating connectors and the used cables
match the connectors in the PSx3xx and are mounted correctly,
in order to achieve the protection class.
2.5.1 Supply voltage connector
connector pattern
(external top view)
assignment
type/producer
1. +24V motor
2. GND motor
3. +24V control unit
4. GND control unit
5. housing/pressure balance
PSE/PSS:
series 713/763 (A-cod.);
5-pol.; Binder
PSW:
series 713/763 (A-cod.);
4-pol. with airtube; Binder
1. +24V motor
2. GND motor
3. +24V control unit
4. GND control unit
5. housing/pressure balance
PSE34xx:
HAN4A, Harting
To prevent the ingression of fluids into the PSW-housing during
cooldown, use a special cable with an airtube for pressure
balancing of your PSW
2.5.2 Round socket for the bus
connector pattern
(external top view)
assignment
type/producer
1. TD+(WH/GN, white/green)
2. RD+ (WH/OG,
white/orange)
3. TD- (GN, green)
4. RD- (OG, orange)
M12 (D-cod.); 4-pol.
Due to the use of 4-pin sockets, only four-wire cables should
be used.
2.5.3 Hybrid bushing for supply and bus
connector pattern
(external top view)
assignment
type/producer
1. TD+
2. TD-
3. RD+
4. RD-
5. GND motor
6. GND control unit
7. +24V motor
8. +24V control unit
M12 (Y-cod.); 8-pol.