APPLIANCE INSTALLATION
UNPACKING THE APPLIANCE
4.1
Before installing the appliance, check that the chosen location is
suitable (section 3.2) and that the requirements for flue position (section
3.3) and minimum clearances (Figure 1b) are satisfied.
The appliance is supplied in one box. Flue kits are provided separately,
the various flue kits available as described in sections 2.5 - 2.7. If the
appliance is to be installed without access to an external wall, a wall
liner kit is also required.
Unpack the boxes and check the contents:
G
Complete appliance
G
Paper wall mounting template
G
Wall mounting plate
G
Installation and Servicing Instruction
G
User's Instructions
G
Warranty Card
G
Hardware pack containing:
50mm x No 10 Wood Screws - 4 off
Rawl Plug to suit - 4 off
Manual Handling Note:
During the appliance installation it will be necessary
to employ caution and assistance whilst lifting, as the
appliance exceeds the recommended weight for a
one-man lift. Take care to avoid trip hazards, slippery
or wet surfaces.
PREPARING THE WALL
4.2
a)
Fix the paper template in the required position (ensuring that the
necessary clearances are achieved). Ensure squareness by hanging
a plumb line.
b)
Mark the position of the wall mounting plate-fixing holes (4). Select
one from each group. Refer to Figure 10.
c)
Mark the position of the flue outlet. For side flue installation extend
the flue centre line on to the sidewall, where the flue length exceeds
775 mm, a flue slope angle of 2.5° needs to be taken into account.
Refer to Figure 10. Remove the paper template.
d)
Cut the hole in the wall for the air/flue duct (preferably with a core-
boring tool). The hole must be horizontal and not be less than 100
mm in diameter. If the hole is not accessible from outside, its
minimum diameter must be sufficient to allow insertion of the wall
liner (130 mm, 5in). The wall liner is available as an optional extra
and must be sealed in position with mortar (or equivalent).
e)
Drill the four fixing holes using a 6mm drill and insert the wall plugs
provided.
f)
Hang the wall mounting plate using two fixing screws in the top,
ensuring that it is level.
MOUNTING THE APPLIANCE
4.3
Refer to Figure 10.
a)
Lift the appliance into position approximately 10 mm above the top
of the wall mounting plate and use the side wings on the plate to
locate the appliance in a horizontal direction. Then carefully lower
the appliance, ensuring that the top locating rail is securely
engaged.
b)
Connect the central heating system pipes to the central heating flow
and return pipes on the boiler.
Pipe work may be routed from above or below the
appliance as required.
9
108
190
190
127.5
POSITION OF
DUCT HOLE
POSITION OF WALL
MOUNTING PLATE
2.5º
101.5
REAR FLUE
SIDE FLUE
16
SINGLE PAGES 20/9/10 09:59 Page 18
Содержание EDEN X Type VBX 30
Страница 29: ...27 7 INTERNAL WIRING DIAGRAMS 31 7 1 FUNCTIONAL FLOW WIRING DIAGRAM SINGLE PAGES 20 9 10 10 00 Page 29...
Страница 40: ...51 1 5 9 2 6 10 3 7 11 4 8 12 38 SINGLE PAGES 20 9 10 10 01 Page 40...
Страница 41: ...SINGLE PAGES 20 9 10 10 01 Page 41...
Страница 42: ...SINGLE PAGES 20 9 10 10 01 Page 42...