Page 3
98958C (Rev. B - 2/13)
(L)VRCTL(R)8*1D, *2C, *3C VRCDTL(R)*C (L)VRCTL(R)DD*C
13 7/8" 35
2m
m
18 3/4" 47
6m
m
37
1
/2
"
95
2m
m
6 1/
2"
166m
m
20
3
/8
"
51
8m
m
26 11
/1
6"
677
m
m
31 11
/16"
80
4m
m
3 1/2" 89
m
m
4 1
/2
"
11
4m
m
5" 127
m
m
10" 254m
m
5 3
/4"
146m
m
5 3/
4"
146m
m
1 3
/8
"
35m
m
1 3/
8"
35
m
m
18
1
/1
6"
45
9m
m
5 3
/4"
146m
m
5 3/4" 146m
m
1 3/8" 35
m
m
1 3/8
"
35
m
m
6 1/
4"
159
m
m
2 7
/1
6"
63
m
m
1 1/
2"
38
m
m
18
5
/8
"
47
4m
m
2 5/8" 67
m
m
8" 203m
m
4 3
/4"
121
m
m
12 5/1
6"
312
m
m
27
"
68
6m
m
31 7
/8
"
81
0m
m
32 1
5/
16"
83
7m
m
39 1
/2"
1003
m
m
HA
NG
ER
B
RA
CKET
FI
JA
DO
R D
E
SU
SP
EN
SIO
N
SUP
PO
RT
D
E
SU
SP
EN
SIO
N
ORIF
IC
E
HE
IG
HT
AL
TU
RA
D
EL
O
RIF
IC
IO
HA
U
TE
U
R D
E
L'
ORIF
IC
E
OR
IF
IC
E
HE
IG
HT
AL
TU
RA
D
EL
ORIFIC
IO
HA
U
TE
U
R D
E
L'
ORI
FIC
E
RI
M
HE
IG
HT
AL
TU
RA
D
EL
ORIF
IC
IO
HA
U
TE
U
R D
E
L '
O
RI
FI
CE
*
B
D
E
E
F
F
A
C
FI
NI
SH
ED
FLO
OR
PI
SO
AC
ABA
DO
PL
AN
CH
ER
FI
NI
5/
16
"
(8
m
m
) D
IA.
(1
0 H
O
LE
S)
8mm
(1
0
AGU
JE
RO
S)
8mm
(1
0
TR
O
U
S)
6 3/
4"
17
3m
m
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM
OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OT
ROS) 3 en. (76 Mm) el MAXIMO
FUERA DE PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR L
ES AUTRES) 3 dans. (76 mm) le MAXIMUM
HORS DU MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2" DE SORTIE D’EAU.
STUB 2 HORS DU MUR
C = 1-1/2 TRAP NOT FURNISHED
PURGADOR DE 1-1/2 NO PROPORCIONADO
SIPHON 1-1/2 NON FOURNI
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152
mm
) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUE
BLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152
mm
) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
* * *
ADA REQUIREMENT
REQUISITO DE A.D.A.
EXIGENCE ADA
FIG. 3
VRCTLR8